Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000402 DEA: 11430384 EFIS: 1118000114
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-23.7/28.5
Work Description: REPLACE DRAINAGE, CONCRETE PAVEMENT, AND MODIFY ELECTRICAL SYSTEMS.
Location Description: SAN DIEGO COUNTY IN SAN DIEGO FROM 0.1 MILE NORTH OF ROUTE 805/52 SEPARATION TO ROUTE 5/805 SEPARATION
Contractor Name: HAZARD CONSTRUCTION ENGR, LLC
Contractor Address: 10529 VINE STREET, LAKESIDE, CA 92040
Resident Engineer: Karl Hartline Structure Rep.: Unknown
DIME Sample ID: 2025-08-25-69
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/25/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/27/2025
The quantity of what the sample constitutes: 12 boxes
A brief description of the sample: PSU
From where was the sample collected: Supplier
Laboratory sample identification: 25-08-25-69-PSU
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Otay
HMA Type: RHMA-G
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number: 326122 Otay SJR
Binder content (%): 7.8
Virgin binder PG: PG 64-16
Design binder PG: PG 64-16
Binder Supplier: SJR
RAP content (%): 0
WMA Additives: Yes
Antistrip type: No
DIME Test ID: 2025-08-25-69-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/05/2025
Date Tested: 09/04/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 7.8% / Tested 7.77% - Saved material for T30
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3960.7 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5503.2 g
|
|
Mass of HMA Sample prior to ignition
|
1542.5 g
|
|
Corrected Asphalt Binder Content
|
7.77 %
|
|
Mass Loss
|
134.9 g
|
|
Mass of aggregate remaining after ignition
|
1407.6 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.98 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2025-08-25-69-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/05/2025
Date Tested: 09/04/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 2.418 / Tested 2.396
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7475.6 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1542.6 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8374.3 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.396
|
|
Theoretical maximum density at 25°C (77°F)
|
149.1 lb/ft^3
|
DIME Test ID: 2025-08-25-69-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 09/05/2025
Date Tested: 09/04/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target Gmb within 0.008 Gmb . Tested Low -2.331 & High 2.335
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.331
|
|
Bulk Specific Gravity 2
|
2.335
|
|
Bulk Specific Gravity 3
|
2.334
|
|
Average Bulk Specific Gravity
|
2.333
|
DIME Test ID: 2025-08-25-69-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 09/05/2025
Date Tested: 09/04/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.0% +/- 1.5% Tested Avg of 2.6%
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
2.7 %
|
|
Percent Air Voids 2
|
2.6 %
|
|
Percent Air Voids 3
|
2.5 %
|
|
Average Percent Air Voids
|
2.6 %
|
DIME Test ID: 2025-08-25-69-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 09/26/2025
Date Tested: 09/25/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target WET > 70 psi & DRY > 100 psi - Tested WET-73 psi & DRY 101 psi
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
101 psi
|
|
Average Wet Tensile Strength
|
73 psi
|
|
Tensile Strength Ratio
|
0.72
|
DIME Test ID: 2025-08-25-69-6
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 09/26/2025
Date Tested: 09/23/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target < 12.7 mm - Tested an Avg of 5.52 mm
Test Result Compliance: complies
Additional Comments When Verified:
|
Specimen Preparation Method
|
PMLC
|
|
Test Temperature
|
122 F
|
|
Air Void Content for specimen A-1
|
no data
|
|
Air Void Content for specimen A-2
|
no data
|
|
Air Void Content for specimen B-1
|
no data
|
|
Air Void Content for specimen B-2
|
no data
|
|
Stripping Inflection Point (Wheel A)
|
>15000
|
|
Stripping Inflection Point (Wheel B)
|
>15000
|
|
Maximum impression at 5000 passes (left wheel)
|
2.33 mm
|
|
Maximum impression at 5000 passes (right wheel)
|
3.23 mm
|
|
Average impression at 5000 passes (left/right avg)
|
2.78 mm
|
|
Maximum impression at 10000 passes (left wheel)
|
3.2 mm
|
|
Maximum impression at 10000 passes (right wheel)
|
4.14 mm
|
|
Average impression at 10000 passes (left/right avg)
|
3.67 mm
|
|
Maximum impression at 15000 passes (left wheel)
|
4.52 mm
|
|
Maximum impression at 15000 passes (right wheel)
|
6.52 mm
|
|
Average impression at 15000 passes (left/right avg)
|
5.52 mm
|
|
Average impression at 20000 passes (left/right avg)
|
no data
|
|
Average impression at 25000 passes (left/right avg)
|
no data
|