Print Report | Back to Sample Detail

Sample Record for 2025-08-11-47

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001104 DEA: 072XR204 EFIS: 0725000163 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-1-VAR
Work Description: BID ITEM : STEEL SOLDIER PILE (W12X120) ASTM A992 Gr 50, Bare Steel, 100% Domestic 38 PILES AVAILABLE IMMEDIATELY FROM STOCK 37 PILES AVAILABLE FROM FUTURE MILL ROLL OF 3/16/25 Supplied as: 75 EA. @ 33'9"
Location Description: PCH
Contractor Name: Myers & Sons Construction
Contractor Address: 45 Morrison Ave, Sacramento, CA 95838
Resident Engineer: Steve Zaw Structure Rep.: Mehrzad Moheb

Sample Information

DIME Sample ID: 2025-08-11-47
TL Number from the TL Form:
Sample Submitted By Organization: Pro-Cast Products, Incorporated - Highland
Sample Organization Contact: (909) 793-7602
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 08/11/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/12/2025
The quantity of what the sample constitutes: 8 cy
A brief description of the sample: Concrete
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pro- Cast Products, Inc.

Material Information

The concrete mix design number: PRO1805125
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 1
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Ready Mix Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 3

DIME Test ID: 2025-08-11-47-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 11/10/2025
Date Tested: 08/11/2025
Submitted By Organization: Pro-Cast Products, Incorporated - Highland
Organization Address: 27417 East Third Street,
Organization City: Highland
Organization State: CA
Organization Zipcode: 92346
Organization Email: bmalott@procastproducts.com
Organization Phone: (909) 809-2429
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 86 F

Test 2 of 3

DIME Test ID: 2025-08-11-47-2
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 11/10/2025
Date Tested: 08/11/2025
Submitted By Organization: Pro-Cast Products, Incorporated - Highland
Organization Address: 27417 East Third Street,
Organization City: Highland
Organization State: CA
Organization Zipcode: 92346
Organization Email: bmalott@procastproducts.com
Organization Phone: (909) 809-2429
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 7.5 inch

Test 3 of 3

DIME Test ID: 2025-08-11-47-3
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 11/10/2025
Date Tested: 09/08/2025
Submitted By Organization: Pro-Cast Products, Incorporated - Highland
Organization Address: 27417 East Third Street,
Organization City: Highland
Organization State: CA
Organization Zipcode: 92346
Organization Email: bmalott@procastproducts.com
Organization Phone: (909) 809-2429
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.56 in^2
Cross sectional area of cylinder 2 12.56 in^2
Cross sectional area of cylinder 3 12.56 in^2
Compressive strength (to nearest 10 psi) 6340 psi
Maximum load on cylinder 1 78440 lb
Maximum load on cylinder 2 79750 lb
Maximum load on cylinder 3 80720 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data