Sample Record for 2025-08-25-44

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993678 DEA: 042Q8004 EFIS: 0419000050 COOP: 042836,042944 QA Service Level: 1
DIST-CO-RTE-PM: 04-SM-101,92-US 101 & SR 92-10.9/12.1 & 11.8/13.4
Work Description: US 101/SR 92 INTERCHANGE AREA IMPROVEMENT :PROJECT WILL CONSTRUCT CONGESTION RELIEF IMPROVEMENTS AT THE US 101/SR 92 INTERCHANGE AREA.
Location Description:
Contractor Name: GORDON N. BALL, INC.
Contractor Address: 333 CAMILLE AVENUE, ALAMO, CA 94507
Resident Engineer: Mohamed Fouad Structure Rep.: Bryan Nagid

Sample Information

DIME Sample ID: 2025-08-25-44
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 08/25/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/26/2025
The quantity of what the sample constitutes: 60
A brief description of the sample: Headed Bar
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Transpacific Steel Yard

Material Information

Production or Authorization Testing: Production Testing
Rebar Heat Number(s): 3500035405
Head Manufacturer Lot Number(s): M0384
Rebar Size: #11
Headed Bar Model Name: nVent LENTON TERMINATOR D14
Size of Head: Full Size - 9x
Head Connection Type:
Head Shape: Circular
Rebar Manufacturer: Nucor
Head Manufacturer: Erico lenton
Head Fabricator: Erico
Material Standard Code: ASTM A706
Headed Bar Unique ID: 9TT-17-02

Test Results

Test 1 of 1

DIME Test ID: 2025-08-25-44-1
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 09/03/2025
Date Tested: 09/03/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 4
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
11.5615174097500Bar Stripped out from HeadKleinfelder
11.5615260098000Bar Stripped out from HeadKleinfelder
11.5613937089500Bar Stripped out from HeadKleinfelder
11.5614901095500Bar Stripped out from HeadKleinfelder
Temperature 0 f
UTM NA