Print Report | Back to Sample Detail

Sample Record for 2025-08-18-48

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000783 DEA: 041Q7004 EFIS: 0418000319 QA Service Level: 1
DIST-CO-RTE-PM: 04-SON-101-22.8/32.8
Work Description: REPLACE BRIDGE RAILING AND GUARDRAIL, & RECONSTRUCT SIDEWALK.
Location Description: SONOMA COUNTY AT VARIOUS LOCATIONS FROM MENDOCINO AVENUE OVERCROSSING TO LIMERICK LANE OVERCROSSING
Contractor Name: GHILOTTI CONSTRUCTION COMPANY, INC.
Contractor Address: Unknown
Resident Engineer: Leonard Brajnikoff Structure Rep.: Nick Abuhamdieh

Sample Information

DIME Sample ID: 2025-08-18-48
TL Number from the TL Form:
Sample Submitted By Organization: CT SC - 3672 - Santa Rosa
Sample Organization Contact: (510) 774-6009
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 08/18/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/26/2025
The quantity of what the sample constitutes: 10
A brief description of the sample: 590CR2
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Superior Supplies Ready Mix

Material Information

The concrete mix design number: 590CR2
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 311692
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2025-08-18-48-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/16/2025
Date Tested: 09/15/2025
Submitted By Organization: Kleinfelder - Hayward
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C39 - Ground End
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.01 in
Average diameter of cylinder 3 4.01 in
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.63 in^2
Cross sectional area of cylinder 3 12.63 in^2
Compressive strength (to nearest 10 psi) 4290 psi
Maximum load on cylinder 1 53816 lb
Maximum load on cylinder 2 56818 lb
Maximum load on cylinder 3 52095 lb
Compressive strength of cylinder 1 4261.0 psi
Type of fracture pattern of cylinder 1 5
Compressive strength of cylinder 2 4498.7 psi
Compressive strength of cylinder 3 4124.7 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data