Print Report | Back to Sample Detail

Sample Record for 2025-08-07-48

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995538 DEA: 024H0604 EFIS: 0218000073 QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU,PLU-36-
Work Description: CHESTER CAUSEWAY REHAB
Location Description: LASSEN AND PLUMAS COUNTIES FROM MELISSA AVENUE TO 0.6 MILE EAST OF RED RIVER CANAL
Contractor Name: HAT CREEK CONSTRUCTION & MATERIALS, INC.
Contractor Address: Unknown
Resident Engineer: Daniel Gibbs Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-08-07-48
TL Number from the TL Form: 875604
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Verification
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/07/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/19/2025
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 1 pan of 1/2-inch HMA-A w/25% RAP PG58-34 Albina
From where was the sample collected: Manufacturer
Laboratory sample identification: D80011
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dig It Construction — Sierra Cascade Aggregate and Asphalt Products (Chester, CA)

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%): 5.9
Virgin binder PG:
Design binder PG: PG 64-28
Binder Supplier: Albina (Klamath Falls, OR)
RAP content (%): 24
WMA Additives: No
Antistrip type: Lime

Test Results

Test 1 of 1

DIME Test ID: 2025-08-07-48-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/26/2025
Date Tested: 08/25/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pb=5.77%, TV=5.85%
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3040.2 g
Mass of the specimen and specimen basket assembly prior to ignition 5180.3 g
Mass of HMA Sample prior to ignition 2140.1 g
Corrected Asphalt Binder Content 5.77 %
Mass Loss 138.9 g
Mass of aggregate remaining after ignition 2001.2 g
Correction Factor (Percent by mass of HMA Specimen) 0.58 %
Moisture Content no data0 %
Temperature Compensation Factor 0.14 %
Test Temperature 538 C