Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000211 DEA: 112N0204 EFIS: 1117000168
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-76-R17.2/24.1
Work Description: COLD PLANE AND OVERLAY WITH RHMA GAP GRADED.
Location Description: SAN DIEGO COUNTY NEAR PALA FROM ROUTE 76/15 SEPARATION TO PALA MISSION ROAD
Contractor Name: GRIFFITH COMPANY
Contractor Address: 13400 Sabre Spring Parkway Ste 200, San Diego, CA 92128
Resident Engineer: Fahad Masud Structure Rep.: Unknown
DIME Sample ID: 2025-08-14-87
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/14/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/15/2025
The quantity of what the sample constitutes: 12 Boxes
A brief description of the sample: PSU
From where was the sample collected: Supplier
Laboratory sample identification: 25-08-14-87-PSU
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta
HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 23417105 MM
Binder content (%): 4.5
Virgin binder PG: PG58-16
Design binder PG: PG58-16
Binder Supplier: Martin Marietta
RAP content (%): 25
WMA Additives: Yes
Antistrip type: Liquid
DIME Test ID: 2025-08-14-87-3
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/28/2025
Date Tested: 08/27/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.45% Tested a 4.94 %
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4035.5 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
6079.6 g
|
|
Mass of HMA Sample prior to ignition
|
2044.1 g
|
|
Corrected Asphalt Binder Content
|
4.94 %
|
|
Mass Loss
|
104.5 g
|
|
Mass of aggregate remaining after ignition
|
1939.6 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.17 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2025-08-14-87-4
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/28/2025
Date Tested: 08/27/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 2.507 Gmb Tested 2.510 Gmb
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7475.6 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2546.6 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
9007.5 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.51
|
|
Theoretical maximum density at 25°C (77°F)
|
156.2 lb/ft^3
|
DIME Test ID: 2025-08-14-87-5
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 08/28/2025
Date Tested: 08/27/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target LOW and HIGH Gmb difference of 0.008 Gmb . Tested a DIFFERENCE OF 0.007 Gmb
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.417
|
|
Bulk Specific Gravity 2
|
2.413
|
|
Bulk Specific Gravity 3
|
2.41
|
|
Average Bulk Specific Gravity
|
2.413
|
DIME Test ID: 2025-08-14-87-6
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 08/28/2025
Date Tested: 08/27/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.0 % +/- 1.5 % . Tested an Avg of 3.9%
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
3.7 %
|
|
Percent Air Voids 2
|
3.9 %
|
|
Percent Air Voids 3
|
4 %
|
|
Average Percent Air Voids
|
3.9 %
|
DIME Test ID: 2025-08-14-87-7
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 09/11/2025
Date Tested: 09/10/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target WET > 70 psi and DRY > 100 psi / Tested WET-119 psi and DRY- 166 psi
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
166 psi
|
|
Average Wet Tensile Strength
|
119 psi
|
|
Tensile Strength Ratio
|
0.72
|
DIME Test ID: 2025-08-14-87-8
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 09/11/2025
Date Tested: 09/09/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target > 12.7 mm Tested an Avg of 1.09 mm
Test Result Compliance: complies
Additional Comments When Verified:
|
Specimen Preparation Method
|
PMLC
|
|
Test Temperature
|
113 F
|
|
Air Void Content for specimen A-1
|
no data
|
|
Air Void Content for specimen A-2
|
no data
|
|
Air Void Content for specimen B-1
|
no data
|
|
Air Void Content for specimen B-2
|
no data
|
|
Stripping Inflection Point (Wheel A)
|
>10000
|
|
Stripping Inflection Point (Wheel B)
|
>10000
|
|
Maximum impression at 5000 passes (left wheel)
|
0.81 mm
|
|
Maximum impression at 5000 passes (right wheel)
|
0.97 mm
|
|
Average impression at 5000 passes (left/right avg)
|
0.89 mm
|
|
Maximum impression at 10000 passes (left wheel)
|
1.01 mm
|
|
Maximum impression at 10000 passes (right wheel)
|
1.16 mm
|
|
Average impression at 10000 passes (left/right avg)
|
1.09 mm
|
|
Average impression at 15000 passes (left/right avg)
|
no data
|
|
Average impression at 20000 passes (left/right avg)
|
no data
|
|
Average impression at 25000 passes (left/right avg)
|
no data
|
DIME Test ID: 2025-08-14-87-9
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/28/2025
Date Tested: 08/28/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 3 RAP burns, save 1 for gradation
Test Result Compliance: not applicable
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3995.5 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5640.9 g
|
|
Mass of HMA Sample prior to ignition
|
1645.4 g
|
|
Corrected Asphalt Binder Content
|
7.37 %
|
|
Mass Loss
|
121.3 g
|
|
Mass of aggregate remaining after ignition
|
1524.1 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data0 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2025-08-14-87-10
Test Method: CTM 375-February 2012: Determining the Density and Relative Compaction of Data Cores (lab)
Verified Date: 12/09/2025
Date Tested: 12/05/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of Cores
|
1
|
|
Core 1 ID
|
1 A
|
|
Dry Weight 1
|
1311.4 grams
|
|
Parrafin Coated Weight 1
|
1327.3 grams
|
|
Coated Weight in Water 1
|
736.9 grams
|
|
Theoretical Maximum Density
|
2.51
|