Print Report | Back to Sample Detail

Sample Record for 2025-08-01-57

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000891 DEA: 120U8104 EFIS: 1224000036 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-57-11.0/22.5
Work Description: REMOVE AND REPLACE RHMA, PAVEMENT MARKING AND ROADSIDE SIGN.
Location Description: ORANGE COUNTY AT VARIOUS LOCATIONS FROM ROUTE 5/22/57 SEPARATION TO 0.3 MILE SOUTH OF LOS ANGELES COUNTY LINE
Contractor Name: AUTOBAHN CONSTRUCTION, INC.
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-08-01-57
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 08/01/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/21/2025
The quantity of what the sample constitutes: 1can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: All American Asphalt Corona

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2025-08-01-57-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 08/25/2025
Date Tested: 08/25/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 69 C
Softening Point Sample 2 69 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test 2 of 3

DIME Test ID: 2025-08-01-57-2
Test Method: ASTM D217-21: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 08/25/2025
Date Tested: 08/23/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Worked Penetration
Worked Penetration 30 0.1 mm

Test 3 of 3

DIME Test ID: 2025-08-01-57-3
Test Method: ASTM D5329-20: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 08/25/2025
Date Tested: 08/23/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Ball Penetration (P1) 2 mm
Final Dial reading (F1) 55 mm
Ball Penetration (P2) 1 mm
Final Dial reading (F2) 54 mm
Ball Penetration (P3) 1 mm
Final Dial reading (F3) 56 mm
Resilience 1 47 %
Resilience 2 47 %
Resilience 3 45 %
Average Resilience 46 %
Minutes Reaction no data