Sample Record for 2025-08-22-13
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994751 DEA: 010C5004 EFIS: 0112000292
QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-36-11.3/34.6
Work Description: Project Name: Bridge Rail Replacement - 3 Bridges
Location Description: Hely Creek, Little Larabee Creek and Butte Creek Bridge.
Contractor Name: Mercer-Fraser Company
Contractor Address: 200 Dinsmore Dr, Fortuna, CA 95540
Resident Engineer: Joaquin Rodriguez Structure Rep.: Adlai Evans
Sample Information
DIME Sample ID: 2025-08-22-13
TL Number from the TL Form:
Sample Submitted By Organization: CT D01 - Boyd Road Field Laboratory
Sample Organization Contact: (707) 496-0974
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 08/22/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/25/2025
The quantity of what the sample constitutes: 31 CY
A brief description of the sample: PCC for a gutter on top of wall.
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Mercer Fraser
Material Information
The concrete mix design number: MF 1.4 slag ae
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 111355
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Back of the concrete truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 4
DIME Test ID: 2025-08-22-13-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 08/29/2025
Date Tested: 08/29/2025
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test: 1 cylinder on 8/29/25
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
1
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Compressive strength of cylinder (to nearest 10 psi)
|
5720 psi
|
|
Maximum load on cylinder 1
|
71881 lb
|
|
Type of fracture pattern of cylinder 1
|
5
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Age of specimen
|
7 days
|
|
Age of specimen in hours
|
no data0 hours
|
Test 2 of 4
DIME Test ID: 2025-08-22-13-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,RSP #1
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
This test has been superseded on 09/19/2025. The corrected test ID is: 2025-08-22-13-4
Reason: retested
Test 3 of 4
DIME Test ID: 2025-08-22-13-3
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 10/03/2025
Date Tested: 10/03/2025
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test: 3 cylinders on 10/3/25 if 28 day break did not exceed 5000 psi
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
4.02 in
|
|
Average diameter of cylinder 2
|
4.02 in
|
|
Cross sectional area of cylinder 1
|
12.69 in^2
|
|
Cross sectional area of cylinder 2
|
12.69 in^2
|
|
Compressive strength (to nearest 10 psi)
|
7180 psi
|
|
Maximum load on cylinder 1
|
93825 lb
|
|
Maximum load on cylinder 2
|
88358 lb
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
42 days
|
|
Age of specimen in hours
|
no data0 hours
|
Test 4 of 4
DIME Test ID: 2025-08-22-13-4
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
Data has not been verified.