Project Information

Project ID: 994321 DEA: 040K1604 EFIS: 0416000044 QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA,CC-80-R7.6/8.0,0.0/13.5
Work Description: CONSTRUCT RHMA, LIGHTING SYSTEM, AND CONCRETE BARRIER.
Location Description: ALAMEDA AND CONTRA COSTA COUNTIES IN ALBANY AND CROCKETT FROM 0.4 MILE SOUTH OF ALAMEDA COUNTY LINE TO 0.2 MILE SOUTH OF POMONA STREET
Contractor Name: Bay Cities Paving & Grading (Jeff Brandt)
Contractor Address: 1450 CIVIC CT, BLDG B #400, CONCORD, CA 94520
Resident Engineer: Wesley Morrison Structure Rep.: Alyssa Inocencio

Sample Information

DIME Sample ID: 2025-08-01-46
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Richmond Field Laboratory
Sample Organization Contact: (510) 231-7151
Type of Sample: Quality Assurance
Type of Material: Aggregate
Sample Taken Date: 08/01/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/01/2025
The quantity of what the sample constitutes: 3 Bags. Bin 1,2,3 of Aggregates
A brief description of the sample: Batch Plant OGFC-O
From where was the sample collected: Fabricator
Laboratory sample identification: Rich_25_375
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: County Asphalt Martinez

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-07-0003
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: County asphalt - Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number:
Lot number: 4
Sublot number: 16
Aggregate Mix Number: L250530

Test Results

Test 1 of 1

DIME Test ID: 2025-08-01-46-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 08/19/2025
Date Tested: 08/01/2025
Submitted By Organization: CT D04 - Richmond Field Laboratory
Organization Address: 3401 Regatta Boulevard,
Organization City: Richmond
Organization State: CA
Organization Zipcode: 94508
Organization Email: santiago.sequeira@dot.ca.gov
Organization Phone: (510) 385-7641
General Comments for this Test: Lot 4 SL 16
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? HMA Gradation
Cumulative percent passing the 2 in. sieve no data
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 98 %
Cumulative percent passing the 3/8 in. sieve 83 %
Cumulative percent passing the #4 sieve 33 %
Cumulative percent passing the #8 sieve 16 %
Cumulative percent passing the #16 sieve 11 %
Cumulative percent passing the #30 sieve 9 %
Cumulative percent passing the #50 sieve 6 %
Cumulative percent passing the #100 sieve 4 %
Cumulative percent passing the #200 sieve 2.5 %