Print Report | Back to Sample Detail

Sample Record for 2025-07-27-27

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995193 DEA: 07356604 EFIS: 0719000026 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-605-R10.2/20.2
Work Description: LANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY.
Location Description: LOS ANGELES COUNTY IN SANTA FE SPRINGS, PICO RIVERA, WHITTIER, CITY OF INDUSTRY AND EL MONTE FROM TELEGRAPH ROAD UNDERCROSSING TO ROUTE 605/10 SEPARATION
Contractor Name: MYERS & SONS CONSTRUCTION, LLC
Contractor Address: 45 Morrison Ave, Sacramento, CA 95838
Resident Engineer: Jerome Arabe Structure Rep.: Tien Chu

Sample Information

DIME Sample ID: 2025-07-27-27
TL Number from the TL Form: 72725
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 07/27/2025
Date that the sample was received by the laboratory/organization performing the testing: 07/27/2025
The quantity of what the sample constitutes: 130 CY
A brief description of the sample: 6X12 PCC cylinders
From where was the sample collected: Supplier
Laboratory sample identification: 25-2414
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CC Myers

Material Information

The concrete mix design number: 700 RSC
The truck number from where the sample was collected: 1
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant: CC Myers
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Loader Bucket
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2025-07-27-27-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 08/19/2025
Date Tested: 08/06/2025
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 5.97 in
Average diameter of cylinder 2 6.04 in
Average diameter of cylinder 3 6.03 in
Cross sectional area of cylinder 1 27.99 in^2
Cross sectional area of cylinder 2 28.65 in^2
Cross sectional area of cylinder 3 28.56 in^2
Compressive strength (to nearest 10 psi) 7140 psi
Maximum load on cylinder 1 203163 lb
Maximum load on cylinder 2 206928 lb
Maximum load on cylinder 3 198153 lb
Compressive strength of cylinder 1 7258.4 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 7222.6 psi
Compressive strength of cylinder 3 6938.1 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 10 days
Age of specimen in hours no data0 hours