Sample Record for 2025-08-18-6
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1000004 DEA: 033H5604 EFIS: 0318000014
QA Service Level: 1
DIST-CO-RTE-PM: 03-PLA,NEV-20,80-VAR
Work Description: STRUCTURAL CONC, BAR REINFORCING STEEL, BRIDGE REMOVAL, HMA, AND JPCP.
Location Description: PLACER AND NEVADA COUNTIES NEAR CISCO GROVE ON ROUTE 80 FROM 0.4 MILE WEST OF LAKE VALLEY OVERCROSSING TO 0.9 MILE EAST OF YUBA PASS SEPARATION AND OVERHEAD AND ON ROUTE 20 AT YUBA PASS SEPARATION AND OVERHEAD
Contractor Name: FLATIRON WEST INC.
Contractor Address: 1200 Concord Ave Suite 465, Concord, CA 94520
Resident Engineer: Tad Sampson Structure Rep.: James 'Jimmer' Ross
Sample Information
DIME Sample ID: 2025-08-18-6
TL Number from the TL Form:
Sample Submitted By Organization: Con-Fab California Corporation - Lathrop
Sample Organization Contact: (209) 249-4700
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 08/18/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/18/2025
The quantity of what the sample constitutes: 1 cubic foot
A brief description of the sample: 1 cubic foot
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: ConFab Lathrop
Material Information
The concrete mix design number: 98NV25AF
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 13021
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Bed 7, 4thTruck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 6
DIME Test ID: 2025-08-18-6-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 09/04/2025
Date Tested: 08/18/2025
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email: dannyc@confabca.com
Organization Phone: (209) 249-4717
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Test 2 of 6
DIME Test ID: 2025-08-18-6-2
Test Method: ASTM C1611-21: Standard Test Method for Slump Flow of Self-Consolidating Concrete
Verified Date: 09/04/2025
Date Tested: 08/18/2025
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email: dannyc@confabca.com
Organization Phone: (209) 249-4717
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
What unit system is used for measurements?
|
inches
|
|
Slump Flow
|
22 in
|
|
Filling the mold procedure
|
Filling Procedure B (Inverted Mold)
|
|
Diameter 1
|
22 in
|
|
Diameter 2
|
22 in
|
|
Visual Stability Index
|
no data0
|
Test 3 of 6
DIME Test ID: 2025-08-18-6-3
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 09/04/2025
Date Tested: 08/18/2025
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email: dannyc@confabca.com
Organization Phone: (209) 249-4717
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Identification of concrete represented by the sample
|
Bed 7, 4th Truck
|
|
Volume of the measure
|
0.25 ft^3
|
|
Density of concrete
|
143.9 lb/ft^3
|
|
Yield of concrete
|
no data
|
|
Relative yield of the batch
|
no data
|
|
Cement content
|
no data
|
|
Air content
|
no data
|
Test 4 of 6
DIME Test ID: 2025-08-18-6-4
Test Method: ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 09/04/2025
Date Tested: 08/18/2025
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email: dannyc@confabca.com
Organization Phone: (209) 249-4717
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Test 5 of 6
DIME Test ID: 2025-08-18-6-5
Test Method: CTM TEMP1-16: Test Method for Monitoring Precast Concrete Curing Temperature (Curing temperature)
Verified Date: 09/04/2025
Date Tested: 08/18/2025
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email: dannyc@confabca.com
Organization Phone: (209) 249-4717
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Precast Maximum Curing Temperature
|
142.5 °F
|
Test 6 of 6
DIME Test ID: 2025-08-18-6-6
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/04/2025
Date Tested: 08/20/2025
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email: dannyc@confabca.com
Organization Phone: (209) 249-4717
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Apparent mass of submerged cylinder 1
|
8.27 lb
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.56 in^2
|
|
Cross sectional area of cylinder 2
|
12.56 in^2
|
|
Cross sectional area of cylinder 3
|
12.56 in^2
|
|
Compressive strength (to nearest 10 psi)
|
6130 psi
|
|
Maximum load on cylinder 1
|
76440 lb
|
|
Maximum load on cylinder 2
|
75300 lb
|
|
Maximum load on cylinder 3
|
78940 lb
|
|
Type of fracture pattern of cylinder 1
|
4
|
|
Type of fracture pattern of cylinder 2
|
5
|
|
Type of fracture pattern of cylinder 3
|
4
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
2 days
|
|
Age of specimen in hours
|
no data0 hours
|
|
Serial number of delivery ticket, if available
|
no data
|