Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000683 DEA: 11056404 EFIS: 1124000359
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-11-0.6/2.7
Work Description: PERFORM GRADING, CONSTRUCT DRAINAGE FACILITIES, SIGNS AND STRIPING.
Location Description: SAN DIEGO COUNTY NEAR SAN DIEGO FROM 0.2 MILE WEST OF SANYO AVENUE UNDERCROSSING TO 0.2 MILE EAST OF SIEMPRE VIVA ROAD OVERCROSSING
Contractor Name: HAZARD CONSTRUCTION ENGR, LLC
Contractor Address: Unknown
Resident Engineer: Steve McMillan Structure Rep.: Unknown
DIME Sample ID: 2025-08-05-75
TL Number from the TL Form:
Sample Submitted By Organization: Thompson Pipe Group - Los Angeles
Sample Organization Contact: (909) 201-5127
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 08/05/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/06/2025
The quantity of what the sample constitutes: 3.1 cy
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Thompson pipe group
The concrete mix design number: CT11DC SILICA FUME
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 2617
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: conveyor belt
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2025-08-05-75-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C1231 - Unbonded Elastomeric Pad Cap Cured in accordance with ASTM C511
Verified Date: 08/16/2025
Date Tested: 08/06/2025
Submitted By Organization: Thompson Pipe Group - Los Angeles
Organization Address: 3011 N. Laurel Ave,
Organization City: Rialto
Organization State: CA
Organization Zipcode: 92377
Organization Email: e.mcdonald@thompsonpipegroup.com
Organization Phone: (951) 446-9274
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Cross sectional area of cylinder 1
|
12.63 in^2
|
|
Cross sectional area of cylinder 2
|
12.63 in^2
|
|
Cross sectional area of cylinder 3
|
12.63 in^2
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Compressive strength (to nearest 10 psi)
|
5540 psi
|
|
Average diameter of cylinder 1
|
4.01 in
|
|
Average diameter of cylinder 2
|
4.01 in
|
|
Average diameter of cylinder 3
|
4.01 in
|
|
Maximum load on cylinder 1
|
70180 lb
|
|
Maximum load on cylinder 2
|
68720 lb
|
|
Maximum load on cylinder 3
|
70830 lb
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
7 days
|
DIME Test ID: 2025-08-05-75-2
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C1231 - Unbonded Elastomeric Pad Cap Cured in accordance with ASTM C511
Verified Date: 10/17/2025
Date Tested: 08/25/2025
Submitted By Organization: Thompson Pipe Group - Los Angeles
Organization Address: 3011 N. Laurel Ave,
Organization City: Rialto
Organization State: CA
Organization Zipcode: 92377
Organization Email: e.mcdonald@thompsonpipegroup.com
Organization Phone: (951) 446-9274
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Cross sectional area of cylinder 1
|
12.63 in^2
|
|
Cross sectional area of cylinder 2
|
12.63 in^2
|
|
Cross sectional area of cylinder 3
|
12.63 in^2
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Compressive strength (to nearest 10 psi)
|
6820 psi
|
|
Average diameter of cylinder 1
|
4.01 in
|
|
Average diameter of cylinder 2
|
4.01 in
|
|
Average diameter of cylinder 3
|
4.01 in
|
|
Maximum load on cylinder 1
|
87560 lb
|
|
Maximum load on cylinder 2
|
89670 lb
|
|
Maximum load on cylinder 3
|
81180 lb
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
14 days
|
DIME Test ID: 2025-08-05-75-3
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C1231 - Unbonded Elastomeric Pad Cap Cured in accordance with ASTM C511
Verified Date: 10/17/2025
Date Tested: 09/08/2025
Submitted By Organization: Thompson Pipe Group - Los Angeles
Organization Address: 3011 N. Laurel Ave,
Organization City: Rialto
Organization State: CA
Organization Zipcode: 92377
Organization Email: e.mcdonald@thompsonpipegroup.com
Organization Phone: (951) 446-9274
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Cross sectional area of cylinder 1
|
12.63 in^2
|
|
Cross sectional area of cylinder 2
|
12.63 in^2
|
|
Cross sectional area of cylinder 3
|
12.63 in^2
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Compressive strength (to nearest 10 psi)
|
7350 psi
|
|
Average diameter of cylinder 1
|
4.01 in
|
|
Average diameter of cylinder 2
|
4.01 in
|
|
Average diameter of cylinder 3
|
4.01 in
|
|
Maximum load on cylinder 1
|
92100 lb
|
|
Maximum load on cylinder 2
|
93550 lb
|
|
Maximum load on cylinder 3
|
92910 lb
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
28 days
|