Print Report | Back to Sample Detail

Sample Record for 2025-07-21-57

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001060 DEA: 112N2344 EFIS: 1124000192 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-15-0.4/T2.8
Work Description: COLD PLANE AC, RHMA-G OVERLAY, PAVEMENT MARKING AND SHOULDER BACKING.
Location Description: SAN DIEGO COUNTY IN SAN DIEGO FROM MAIN STREET UNDERCROSSING TO 0.6 MILE NORTH OF ROUTE 15/94 SEPARATION
Contractor Name: HAZARD CONSTRUCTION ENGR, LLC
Contractor Address: Unknown
Resident Engineer: Alex Balce Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-07-21-57
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Per Request
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/21/2025
Date that the sample was received by the laboratory/organization performing the testing: 07/22/2025
The quantity of what the sample constitutes: 4 Boxes
A brief description of the sample: Plant Sample
From where was the sample collected: Supplier
Laboratory sample identification: 25-07-21-57-A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Otay

Material Information

HMA Type: RHMA-G
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number: 326122 Otay SJR
Binder content (%): 7.8
Virgin binder PG: PG 64-16
Design binder PG: PG 64-16
Binder Supplier: San Joaquin Refinery
RAP content (%): 0
WMA Additives: Yes
Antistrip type: No

Test Results

Test 1 of 2

DIME Test ID: 2025-07-21-57-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/19/2025
Date Tested: 08/19/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Target - 7.8% Does Not Comply
Test Result Compliance: does not comply
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3944.5 g
Mass of the specimen and specimen basket assembly prior to ignition 5452 g
Mass of HMA Sample prior to ignition 1507.5 g
Corrected Asphalt Binder Content 7.28 %
Mass Loss 124.5 g
Mass of aggregate remaining after ignition 1383 g
Correction Factor (Percent by mass of HMA Specimen) 0.98 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C

Test 2 of 2

DIME Test ID: 2025-07-21-57-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/19/2025
Date Tested: 08/19/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Target - 2.418 Complies
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7475.6 grams
Mass of oven-dry sample in air for Sample 1 1509.4 grams
Mass of container filled with the sample and water for Sample 1 8365.4 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.436
Theoretical maximum density at 25°C (77°F) 151.6 lb/ft^3