Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1001111 DEA: 010M6504 EFIS: 0123000052
QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-101-125.7/R131.7
Work Description: REPLACE AC SURFACING AND DELINEATION.
Location Description: HUMBOLDT COUNTY ON ROUTE 101 FROM 0.40 MILE SOUTH OF SOUTH PRAIRIE CREEK UNDERCROSSING TO 2.76 MILES NORTH OF BOYES CREEK VIADUCT
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2025-08-13-22
TL Number from the TL Form:
Sample Submitted By Organization: CT D01 - Crescent City Field Laboratory
Sample Organization Contact: (707) 496-5581
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/13/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/13/2025
The quantity of what the sample constitutes: 4 Boxes HMA
A brief description of the sample: sample at 1250 tons
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kernen Blue Lake Plant
DIME Test ID: 2025-08-13-22-1
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 08/21/2025
Date Tested: 08/21/2025
Submitted By Organization: CT D01 - Crescent City Field Laboratory
Organization Address: 1444 Parkway Dr.,
Organization City: Crescent City
Organization State: CA
Organization Zipcode: 95531
Organization Email: clayton.malmberg@dot.ca.gov
Organization Phone: (707) 496-5581
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Is an aggregate correction factor used?
|
No
|
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
93 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
84 %
|
|
Cumulative percent passing the #4 sieve
|
56 %
|
|
Cumulative percent passing the #8 sieve
|
36 %
|
|
Cumulative percent passing the #16 sieve
|
25 %
|
|
Cumulative percent passing the #30 sieve
|
18 %
|
|
Cumulative percent passing the #50 sieve
|
13 %
|
|
Cumulative percent passing the #100 sieve
|
9 %
|
|
Cumulative percent passing the #200 sieve
|
6.3 %
|
DIME Test ID: 2025-08-13-22-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/21/2025
Date Tested: 08/19/2025
Submitted By Organization: CT D01 - Crescent City Field Laboratory
Organization Address: 1444 Parkway Dr.,
Organization City: Crescent City
Organization State: CA
Organization Zipcode: 95531
Organization Email: clayton.malmberg@dot.ca.gov
Organization Phone: (707) 496-5581
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3960.3 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5833.9 g
|
|
Mass of HMA Sample prior to ignition
|
1873.6 g
|
|
Corrected Asphalt Binder Content
|
4.83 %
|
|
Mass Loss
|
112.5 g
|
|
Mass of aggregate remaining after ignition
|
1761.1 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
1.17 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
482 C
|