Project Information

Project ID: 995254 DEA: 040P9204 EFIS: 0418000026 QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-680-6.4/6.6
Work Description: HMA AND RHMA SURFACING, DECK REPAIR, POLYESTER OVERLAY AND JOIN SEALS
Location Description: ALAMEDA COUNTY IN FREMONT FROM 0.1 MILE SOUTH OF MISSION SAN JOSE 680/238 SEPARATION TO 0.3 MILE NORTH OF MISSION SAN JOSE 680/238 SEPARATION
Contractor Name: MYERS & SONS CONSTRUCTION, LLC.
Contractor Address: 45 Morrison Avenue, Sacramento, CA 95838
Resident Engineer: Scott Sowko Structure Rep.: Jordan Jarosz

Sample Information

DIME Sample ID: 2025-07-26-4
TL Number from the TL Form:
Sample Submitted By Organization: CT SC - 3674 - Livermore
Sample Organization Contact: (510) 393-1493
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/26/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/13/2025
The quantity of what the sample constitutes: 159.7 CY
A brief description of the sample: Rapid set concrete mix
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: Mission San Jose Separation (MODIFY)
The fabricator/manufacturer/facility name: Myers

Material Information

The concrete mix design number: 675CTSRSC
The truck number from where the sample was collected: Load 11 and 21
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: back of truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2025-07-26-4-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/28/2025
Date Tested: 08/23/2025
Submitted By Organization: Kleinfelder - Hayward
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test: 1-1,1-2,1-3 Labeled Samples were damaged during Day 3 curing.
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 3360 psi
Maximum load on cylinder 1 43318 lb
Maximum load on cylinder 2 40796 lb
Maximum load on cylinder 3 42645 lb
Compressive strength of cylinder 1 3446.1 psi
Type of fracture pattern of cylinder 1 6
Compressive strength of cylinder 2 3245.5 psi
Compressive strength of cylinder 3 3392.6 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data

Test 2 of 2

DIME Test ID: 2025-07-26-4-2
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/28/2025
Date Tested: 08/23/2025
Submitted By Organization: Kleinfelder - Hayward
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test: 2-1,2-2,2-3 Labeled
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 3.99 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.5 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 5410 psi
Maximum load on cylinder 1 70529 lb
Maximum load on cylinder 2 64493 lb
Maximum load on cylinder 3 68742 lb
Compressive strength of cylinder 1 5610.9 psi
Type of fracture pattern of cylinder 1 5
Compressive strength of cylinder 2 5159.4 psi
Compressive strength of cylinder 3 5468.7 psi
Type of fracture pattern of cylinder 2 6
Type of fracture pattern of cylinder 3 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data