Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994751 DEA: 010C5004 EFIS: 0112000292 QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-36-11.3/34.6
Work Description: Project Name: Bridge Rail Replacement - 3 Bridges
Location Description: Hely Creek, Little Larabee Creek and Butte Creek Bridge.
Contractor Name: Mercer-Fraser Company
Contractor Address: 200 Dinsmore Dr, Fortuna, CA 95540
Resident Engineer: Joaquin Rodriguez Structure Rep.: Adlai Evans

Sample Information

DIME Sample ID: 2025-08-12-46
TL Number from the TL Form:
Sample Submitted By Organization: CT D01 - Boyd Road Field Laboratory
Sample Organization Contact: (707) 496-0974
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 08/12/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/13/2025
The quantity of what the sample constitutes: 11 CY
A brief description of the sample: PCC with slag and air entrainment.
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: Little Larabe Creek Bridge
The fabricator/manufacturer/facility name: Mercer Fraser

Material Information

The concrete mix design number: MF CL 1 .40 SLAG AE
The truck number from where the sample was collected: 683
The batch plant ticket number from where the sample was collected: 111152
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete dischanged from the truck
Where the material sample would have been placed if not sampled: Abutment 1 wingwall
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2025-08-12-46-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 08/19/2025
Date Tested: 08/19/2025
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test: 1 cylinder break at 7 days, 8/19/25
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 1
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Compressive strength of cylinder (to nearest 10 psi) 5410 psi
Maximum load on cylinder 1 68060 lb
Type of fracture pattern of cylinder 1 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Age of specimen 7 days
Age of specimen in hours no data0 hours

Test 2 of 2

DIME Test ID: 2025-08-12-46-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 09/09/2025
Date Tested: 09/09/2025
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test: 2 cylinder-28 day breaks on 9/9/25. If cylinders exceed 5000 psi, break 3rd cylinder. If average strength is below 5000 psi, reserve 3 remaining cylinders for 42 day break.
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 6650 psi
Maximum load on cylinder 1 86281 lb
Maximum load on cylinder 2 78916 lb
Maximum load on cylinder 3 85645 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2025-08-12-46-3CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders08/18/202509/23/2025Leif AyresCT D01 - District 1 Materials Laboratory3 cylinders, break on 9/23/25 if the 28 day breaks are under 5000 psi.Jamie Kelley