Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1001001 DEA: 081N7704 EFIS: 0823000047
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-173-L0.0/L7.7
Work Description: COLD PLANE AC PVMT, HMA (TYPE A), AND REPLACE AC SURFACING.
Location Description: SAN BERNARDINO COUNTY IN HESPERIA FROM ROUTE 138 TO 0.5 MILE EAST OF ARROWHEAD LAKE ROAD
Contractor Name: CALMEX ENGINEERING, INC.
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2025-08-07-18
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/07/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/08/2025
The quantity of what the sample constitutes: 4 BOXES OF HMA, 1 QT PG58-22
A brief description of the sample: 1/2" WMA A SP RAP 20% EVO .50%
From where was the sample collected: Manufacturer
Laboratory sample identification: 0497A-25
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Oro Grande
DIME Test ID: 2025-08-07-18-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/18/2025
Date Tested: 08/10/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
1614.1 g
|
|
Corrected Asphalt Binder Content
|
4.97 %
|
|
Mass Loss
|
88.5 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.33 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.19 %
|
|
Test Temperature
|
538 C
|