Print Report | Back to Sample Detail

Sample Record for 2025-07-23-86

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215734 DEA: 024H0104 EFIS: 0218000068 QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-70-78.3/90.3
Work Description: REPLACE AC SURFACING, PLACE HMA AND THERMOPLASTIC TRAFFIC STRIPING.
Location Description: PLUMAS COUNTY NEAR PORTOLA FROM 0.4 MILE WEST OF BIG GRIZZLY CREEK BRIDGE TO 0.8 MILE WEST OF SUMMIT SCHOOL DRIVE
Contractor Name: HAT CREEK CONSTRUCTION & MATERIALS, INC.
Contractor Address: 243339 Hwy 89, N Burney, CA 96013
Resident Engineer: Mike Zdenek Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-07-23-86
TL Number from the TL Form: 815574
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/23/2025
Date that the sample was received by the laboratory/organization performing the testing: 07/28/2025
The quantity of what the sample constitutes: 1 Pan
A brief description of the sample: 1/2-inch HMA-A w/25% RAP PG58-22 Albina
From where was the sample collected: Manufacturer
Laboratory sample identification: D79975
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hat Creek Construction and Materials - Ward Lake Plant (Litchfield, CA)

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%): 6.2
Virgin binder PG: PG 58-22
Design binder PG: PG 64-16
Binder Supplier: Albina
RAP content (%): 25
WMA Additives: No
Antistrip type: Lime

Test Results

Test 1 of 1

DIME Test ID: 2025-07-23-86-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/07/2025
Date Tested: 08/04/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pb=5.52%
Test Result Compliance: does not comply
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3039.4 g
Mass of the specimen and specimen basket assembly prior to ignition 4598.4 g
Mass of HMA Sample prior to ignition 1559 g
Corrected Asphalt Binder Content 5.52 %
Mass Loss 102.6 g
Mass of aggregate remaining after ignition 1456.4 g
Correction Factor (Percent by mass of HMA Specimen) 0.87 %
Moisture Content no data0 %
Temperature Compensation Factor 0.19 %
Test Temperature 538 C