Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 044G5104 Cty SOL Rte 80 PM 31.4,32.6 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Quang Tran |
Date Reported: |
08/25/2017 |
|
Address: |
TL Number: |
209609 |
||
City: |
||||
Project Name: BRIDGE CONSTRUCTION |
||||
Prime Contractor: MCM CONSTRUCTION |
||||
Sample Taken Date: |
07/28/2017 |
Mix Design: |
1582948 |
|
Contractor: Unknown |
Location : SOLANO COUNTY IN AND NEAR VACAVILLE AT MERIDIAN ROAD OVERCROSSING AND AT MIDWAY ROAD OVERCROSSING |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.03 | 28.56 | 105761 | 3703.1 | 1 |
2 | 6.03 | 28.56 | 102931 | 3604.0 | 1 |
DIME Test ID: 2017-07-28-24-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3650
Age of specimen: 28 days
Certified By: Bang Nguyen
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing