Project ID: 1000414 DEA: 034H8704 EFIS: 0319000070
QA Service Level: 1
DIST-CO-RTE-PM: 03-SUT-99-25.0/26.2
Work Description: RDWY EXC, PLACE HMA-A AND CRCP, INSTALL SIGNAL AND LIGHTING.
Location Description: SUTTER COUNTY NEAR YUBA CITY FROM 0.6 MILE SOUTH TO 0.6 MILE NORTH OF OSWALD ROAD
Contractor Name: O.C. JONES & SONS, INC.
Contractor Address: Unknown
Resident Engineer: Dustin Horse Structure Rep.: Unknown
DIME Sample ID: 2025-08-02-1
TL Number from the TL Form: C947165
Sample Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Sample Organization Contact: (530) 741-4238
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/02/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/04/2025
The quantity of what the sample constitutes: 2 Boxes
A brief description of the sample: 1/2" OGFC
From where was the sample collected: Source
Laboratory sample identification: Daily 25-136
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Hallwood
DIME Test ID: 2025-08-02-1-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/05/2025
Date Tested: 08/05/2025
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: L1
OBC 5.3
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
1647.3 g
|
|
Corrected Asphalt Binder Content
|
5.17 %
|
|
Mass Loss
|
93.5 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.51 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.02 %
|
|
Test Temperature
|
538 C
|