Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000478 DEA: 020K6404 EFIS: 0223000189
QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS-97-18.0/22.4
Work Description: CONSTRUCT WILDLIFE OVERPASS, INSTALL CULVERT, AND INSTALL FENCING.
Location Description: SISKIYOU COUNTY NEAR GRASS LAKE FROM 1.4 MILES NORTH OF DEER MOUNTAIN ROAD TO 0.6 MILE NORTH OF GRASS LAKE REST AREA
Contractor Name: MCCUEN CONSTRUCTION, INC.
Contractor Address: 3269 Swetzer Road, Loomis, CA 95650
Resident Engineer: Austin Henry Structure Rep.: Carlos Paz
DIME Sample ID: 2025-08-04-16
TL Number from the TL Form:
Sample Submitted By Organization: Precast Unlimited Inc.
Sample Organization Contact: (530) 243-6477
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 08/04/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/04/2025
The quantity of what the sample constitutes: 1 cubic ft. of Concrete for Testing
A brief description of the sample: 1 cubic ft. of Concrete for Testing
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: JF Shea Construction, Shasta Redi-Mix, Redding, CA
The concrete mix design number: CT850SLA50
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 99875
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Back of Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2025-08-04-16-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 08/04/2025
Date Tested: 08/04/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2025-08-04-16-2
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 08/04/2025
Date Tested: 08/04/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Identification of concrete represented by the sample
|
MCC8425
|
|
Volume of the measure
|
0.25 ft^3
|
|
Density of concrete
|
141.9 lb/ft^3
|
|
Yield of concrete
|
no data
|
|
Relative yield of the batch
|
no data
|
|
Cement content
|
no data
|
|
Air content
|
no data
|
DIME Test ID: 2025-08-04-16-3
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 08/04/2025
Date Tested: 08/04/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2025-08-04-16-4
Test Method: ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 08/04/2025
Date Tested: 08/04/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2025-08-04-16-5
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/02/2025
Date Tested: 09/02/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Apparent mass of submerged cylinder 1
|
8.5 lb
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.56 in^2
|
|
Cross sectional area of cylinder 2
|
12.56 in^2
|
|
Cross sectional area of cylinder 3
|
12.56 in^2
|
|
Compressive strength (to nearest 10 psi)
|
5910 psi
|
|
Maximum load on cylinder 1
|
73450 lb
|
|
Maximum load on cylinder 2
|
78510 lb
|
|
Maximum load on cylinder 3
|
70830 lb
|
|
Type of fracture pattern of cylinder 1
|
6
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
6
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
29 days
|
|
Age of specimen in hours
|
no data0 hours
|
|
Serial number of delivery ticket, if available
|
no data
|