Sample Record for 2025-08-04-10
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994828 DEA: 043Y4104 EFIS: 0423000232
QA Service Level: 1
DIST-CO-RTE-PM: 04-CC,SM-680-25.04/25.46, VAR/VAR
Work Description: Paint removal and non-destructive testing (NDT) on butt weld connections on T1 type steel in fracture critical members of three distinct existing toll bridge.
Location Description: Carquinez Bridge Overhead (Br. No. 23-0015R), Benicia-Martinez Bridge Overhead (Br. No. 28-0153L), and San Mateo-Hayward Bridge (Br. No. 35-0054). County = SM,CC,SOL. Route = 680,80,92.
Contractor Name: Golden State Bridge Inc.
Contractor Address: Unknown
Resident Engineer: Kingston Atako Structure Rep.: Angelo Perez
Sample Information
DIME Sample ID: 2025-08-04-10
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Vallejo Field Laboratory
Sample Organization Contact: 9166394315
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 08/04/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/05/2025
The quantity of what the sample constitutes: 301
A brief description of the sample: 1-8" x 4-3/4" ASTM F3125 GR A490 HEAVY HEX BOLT
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Bay Bolt Oakland, Ca
Material Information
Rocap Number(s): 2563-08
Heat Number(s): Bolt 10898960
Nut 8000029711
Washer 240155
Nut Mfg. Lot Number(s): W000168538
Washer Mfg. Lot Number(s): 186494
Bolt Specification: ASTM F3125
Bolt Length(s): 4-3/4"
Nut Specification: ASTM A563
Washer Specification: ASTM F436
Finish: Plain
Diameter/Size: 1"
Bolt Mfg. Lot Number: E492Q1
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):
Test Results
Test 1 of 10
DIME Test ID: 2025-08-04-10-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 08/20/2025
Date Tested: 08/19/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E492Q1
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
1 in
|
|
Bolt Length
|
4.75 in
|
|
Pitch Diameter
|
0.9101 in
|
|
Pitch Diameter 2nd
|
0.9101 in
|
Test 2 of 10
DIME Test ID: 2025-08-04-10-2
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 08/20/2025
Date Tested: 08/19/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E492Q1
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
1 in
|
|
Bolt Length
|
4.75 in
|
|
Pitch Diameter
|
0.9103 in
|
|
Pitch Diameter 2nd
|
0.9103 in
|
Test 3 of 10
DIME Test ID: 2025-08-04-10-3
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 08/20/2025
Date Tested: 08/19/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E492Q1
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
1 in
|
|
Bolt Length
|
4.75 in
|
|
Pitch Diameter
|
0.9109 in
|
|
Pitch Diameter 2nd
|
0.9109 in
|
Test 4 of 10
DIME Test ID: 2025-08-04-10-4
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/20/2025
Date Tested: 08/19/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
W000168538
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
1 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
31
|
|
Spacing
|
Ok
|
Test 5 of 10
DIME Test ID: 2025-08-04-10-5
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/20/2025
Date Tested: 08/19/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
W000168538
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
1 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
30
|
|
Spacing
|
Ok
|
Test 6 of 10
DIME Test ID: 2025-08-04-10-6
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/20/2025
Date Tested: 08/19/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
W000168538
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
1 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
31
|
|
Spacing
|
Ok
|
Test 7 of 10
DIME Test ID: 2025-08-04-10-7
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/20/2025
Date Tested: 08/19/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
186494
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
1 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
42
|
|
Spacing
|
Ok
|
Test 8 of 10
DIME Test ID: 2025-08-04-10-8
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/20/2025
Date Tested: 08/19/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
186494
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
1 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
43
|
|
Spacing
|
Ok
|
Test 9 of 10
DIME Test ID: 2025-08-04-10-9
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/20/2025
Date Tested: 08/19/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
186494
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
1 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
41
|
|
Spacing
|
Ok
|
Test 10 of 10
DIME Test ID: 2025-08-04-10-10
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 08/20/2025
Date Tested: 08/19/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
3
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | | 1A | E492Q1 | 1 | 103770 | 0 | NA | WSP | | 1B | E492Q1 | 1 | 103395 | 0 | NA | WSP | | 1C | E492Q1 | 1 | 103740 | 0 | NA | WSP |
| |
|
UTM
|
NA
|
|
Temperature
|
72 f
|