Project Information

Project ID: 994588 DEA: 081H3904 EFIS: 0817000032 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-R20.5/R21.6,R25.5/R30.7
Work Description: CONSTRUCT BUILDING, ROADWAY EXC, JPCP, AND TEMPORARY BARRIER SYSTEM.
Location Description: SAN BERNARDINO COUNTY FROM 0.6 MILE NORTH OF CLEGHORN ROAD UNDERCROSSING TO 0.5 MILE SOUTH OF ROUTE 138 AND FROM 0.5 MILE SOUTH OF TRUCK SAFETY CHECK AREA TO 0.4 MILE NORTH OF OAK HILL ROAD OVERCROSSING
Contractor Name: POWELL CONSTRUCTORS INC
Contractor Address: 8555 BANANA AVE, FONTANA, CA 92335
Resident Engineer: Mauricio Santa Cruz Structure Rep.: Oluwatayo (Tayo) Ogeyemi

Sample Information

DIME Sample ID: 2025-07-29-63
TL Number from the TL Form: 1059-C3
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/29/2025
Date that the sample was received by the laboratory/organization performing the testing: 07/29/2025
The quantity of what the sample constitutes: 3
A brief description of the sample: Concrete Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 1059- C3
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hi Grade

Material Information

The concrete mix design number: NOT PROVIDED
The truck number from where the sample was collected: 291
The batch plant ticket number from where the sample was collected: 2009383
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Thermal poles at A station 696+06, Speed sign pole at A Station 698+50, Light pole at A 689+00
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2025-07-29-63-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C1231 - Unbonded Elastomeric Pad Cap
Cured in accordance with ASTM C511
Verified Date: 08/05/2025
Date Tested: 08/05/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Compressive strength (to nearest 10 psi) 2840 psi
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Compressive strength of cylinder 1 2743.0 psi
Compressive strength of cylinder 2 3041.4 psi
Average diameter of cylinder 3 4.00 in
Compressive strength of cylinder 3 2732.7 psi
Maximum load on cylinder 1 34480 lb
Maximum load on cylinder 2 38230 lb
Maximum load on cylinder 3 34350 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days