Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2025-06-12-112
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Authorization
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 06/12/2025
Date that the sample was received by the laboratory/organization performing the testing: 06/16/2025
The quantity of what the sample constitutes: NA
A brief description of the sample: 1 inch ASTM A722, 150 ksi-threaded bar anchorage system, with Anchor Nut, Coupler and Bearing plate with countersunk hole
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dywidag Systems
Production or Authorization Testing: Authorization Testing
Threaded Bar Specification: ASTM A722
Threaded Bar Grade: 150
Threaded Bar Type: Deformed
Rebar Size: #8
Nut Specification for Threaded Bar: ASTM A897
System Manufacturer: Dywidag Systems
Epoxy Coating Color: NA
Threaded Bar Application: Threaded Bar
Coating Standards: Uncoated
Bar Heat Number(s): 58064779/04
Nut Heat Number(s): A095
Bar Lot Number:
Nut Lot Number: L184
Coupler Heat Number(s): C223276
Coupler Grade:
DIME Test ID: 2025-06-12-112-1
Test Method: ASTM A722-18: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 08/21/2025
Date Tested: 08/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Threaded Bar Samples
|
6
|
| Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By | | 1 | 1 | 5806477904 | 0.85 | 156000 | 121200 | 0000 | 0000 | A722 Bar, Nut, Coupler | Atlas | | 2 | 1 | 5806477904 | 0.85 | 161500 | 120300 | 0000 | 0000 | A722 Bar, Nut, Coupler | Atlas | | 3 | 1 | 5806477904 | 0.85 | 162200 | 121600 | 0000 | 0000 | A722 Bar, Nut, Coupler | Atlas | | 4 | 1 | 5806477904 | 0.85 | 161700 | 125000 | 0000 | 0000 | A722 Bar, Nut, Coupler | Atlas | | 5 | 1 | 5806477904 | 0.693 | 161100 | 133900 | 8 | 33 | A722 Bar and Nut | Atlas | | 6 | 1 | 5806477904 | 0.85 | 156900 | 130700 | 9 | 0000 | A722 Bar and Nut | Atlas |
| |
|
Temperature
|
0 f
|
|
UTM
|
NA
|