Print Report | Back to Sample Detail

Sample Record for 2025-01-14-52

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994396 DEA: 07330304 EFIS: 0716000213 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-10-22.0/30.8
Work Description: CONSTRUCT CONCRETE BARRIER AND STRUCTURAL CONCRETE BARRIER SLAB.
Location Description: LOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM 0.6 MILE EAST OF ROUTE 710/10 SEPARATION TO 0.3 MILE WEST OF ROUTE 10/605 SEPARATION
Contractor Name: FEC FUTURE CONTRACTORS AND ENGINEERS, INC.
Contractor Address: 184 TECHNOLOGY DRIVE, SUITE 2, IRVINE CA 92618
Resident Engineer: Edgar Herrera Structure Rep.: Ryan Ramos

Sample Information

DIME Sample ID: 2025-01-14-52
TL Number from the TL Form:
Sample Submitted By Organization: RMA Group - Rancho Cucamonga
Sample Organization Contact: (909) 989-1751
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 01/14/2025
Date that the sample was received by the laboratory/organization performing the testing: 01/14/2025
The quantity of what the sample constitutes: 6 cylinders
A brief description of the sample: SC
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: Barrier
The fabricator/manufacturer/facility name: CEMEX

Material Information

The concrete mix design number: 1610974
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 31480206
Concrete batch plant: CEMEX
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Location 14, Barrier
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 3

DIME Test ID: 2025-01-14-52-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 08/01/2025
Date Tested: 01/16/2025
Submitted By Organization: RMA Group - Rancho Cucamonga
Organization Address: 12130 Santa Margarita Court,
Organization City: Rancho Cucamonga
Organization State: CA
Organization Zipcode: 91730
Organization Email: cbachler@rmacompanies.com
Organization Phone: (909) 989-1751
General Comments for this Test: Avg. Compressive Strength = 1560psi
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With density determined by dimension measurements
Average cylinder density (to nearest 1 pcf) 148 lb/ft^3
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Comment on any defect in either specimen or caps (Max 250 Characters) no data

Test 2 of 3

DIME Test ID: 2025-01-14-52-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 08/01/2025
Date Tested: 01/21/2025
Submitted By Organization: RMA Group - Rancho Cucamonga
Organization Address: 12130 Santa Margarita Court,
Organization City: Rancho Cucamonga
Organization State: CA
Organization Zipcode: 91730
Organization Email: cbachler@rmacompanies.com
Organization Phone: (909) 989-1751
General Comments for this Test: Avg. Compressive Strength = 4560psi
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With density determined by dimension measurements
Average cylinder density (to nearest 1 pcf) 148 lb/ft^3
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Comment on any defect in either specimen or caps (Max 250 Characters) no data

Test 3 of 3

DIME Test ID: 2025-01-14-52-3
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 08/01/2025
Date Tested: 02/11/2025
Submitted By Organization: RMA Group - Rancho Cucamonga
Organization Address: 12130 Santa Margarita Court,
Organization City: Rancho Cucamonga
Organization State: CA
Organization Zipcode: 91730
Organization Email: cbachler@rmacompanies.com
Organization Phone: (909) 989-1751
General Comments for this Test: Avg. Compressive Strength = 7140psi
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With density determined by dimension measurements
Average cylinder density (to nearest 1 pcf) 148 lb/ft^3
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Comment on any defect in either specimen or caps (Max 250 Characters) no data