Print Report | Back to Sample Detail

Sample Record for 2025-06-26-103

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995193 DEA: 07356604 EFIS: 0719000026 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-605-R10.2/20.2
Work Description: LANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY.
Location Description: LOS ANGELES COUNTY IN SANTA FE SPRINGS, PICO RIVERA, WHITTIER, CITY OF INDUSTRY AND EL MONTE FROM TELEGRAPH ROAD UNDERCROSSING TO ROUTE 605/10 SEPARATION
Contractor Name: MYERS & SONS CONSTRUCTION, LLC
Contractor Address: 45 Morrison Ave, Sacramento, CA 95838
Resident Engineer: Jerome Arabe Structure Rep.: Tien Chu

Sample Information

DIME Sample ID: 2025-06-26-103
TL Number from the TL Form:
Sample Submitted By Organization: Alta Vista Solutions - Whittier
Sample Organization Contact: (510) 542-9827
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 06/26/2025
Date that the sample was received by the laboratory/organization performing the testing: 06/26/2025
The quantity of what the sample constitutes: 20 CY
A brief description of the sample: SC590B39
From where was the sample collected: Job Site
Laboratory sample identification: 25-2095
Structure unique identifier:
Structure name: NB 605 @ Whittier Blvd OS15-2
The fabricator/manufacturer/facility name: N/A

Material Information

The concrete mix design number: SC590B39
The truck number from where the sample was collected: Truck or Ticket 1559039
The batch plant ticket number from where the sample was collected: Load 2
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Jobsite
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2025-06-26-103-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 07/30/2025
Date Tested: 07/24/2025
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.03 in
Average diameter of cylinder 2 4.01 in
Average diameter of cylinder 3 4.03 in
Cross sectional area of cylinder 1 12.76 in^2
Cross sectional area of cylinder 2 12.63 in^2
Cross sectional area of cylinder 3 12.76 in^2
Compressive strength (to nearest 10 psi) 5910 psi
Maximum load on cylinder 1 75634 lb
Maximum load on cylinder 2 74944 lb
Maximum load on cylinder 3 75018 lb
Compressive strength of cylinder 1 5927.4 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 5933.8 psi
Compressive strength of cylinder 3 5879.2 psi
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours