Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994673 DEA: 033F0704 EFIS: 0312000054
QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC-51-2.0/3.5
Work Description: American River Bridge Rehabilitation
Location Description:
Contractor Name: American River Constructors
Contractor Address: 4001 Bradshaw Road, Sacramento, CA 95827
Resident Engineer: John Ruzic Structure Rep.: Pha Tran
DIME Sample ID: 2025-07-29-10
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/29/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/07/2025
The quantity of what the sample constitutes: 95 Bolts
A brief description of the sample: A325 HDG Bolts
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: L&B Metal Product Fabrication
Rocap Number(s):
Heat Number(s): 10922800
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: ASTM A325
Bolt Length(s): 2-1/2"
Nut Specification: N/A
Washer Specification: N/a
Finish: HDG, ASTM A153/F3253
Diameter/Size: 3/4"
Bolt Mfg. Lot Number: BG2988
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):
DIME Test ID: 2025-07-29-10-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 09/15/2025
Date Tested: 09/12/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
BG2988
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
2.5 in
|
|
Pitch Diameter
|
0.6884 in
|
|
Pitch Diameter 2nd
|
0.6884 in
|
DIME Test ID: 2025-07-29-10-2
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 09/15/2025
Date Tested: 09/12/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
BG2988
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
2.5 in
|
|
Pitch Diameter
|
0.6987 in
|
|
Pitch Diameter 2nd
|
0.6987 in
|
DIME Test ID: 2025-07-29-10-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/15/2025
Date Tested: 09/12/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
BG2988
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
2.5 in
|
|
Measurement Average
|
3.6 mils
|
DIME Test ID: 2025-07-29-10-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/15/2025
Date Tested: 09/12/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
BG2988
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
2.5 in
|
|
Measurement Average
|
5.3 mils
|
DIME Test ID: 2025-07-29-10-5
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 09/15/2025
Date Tested: 09/12/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
2
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | | 1A | BG2988 | 0.75 | 49600 | 0 | NA | W Torres | | 1B | BG2988 | 0.75 | 48780 | 0 | NA | W Torres |
| |
|
UTM
|
NA
|
|
Temperature
|
72 f
|