Print Report | Back to Sample Detail

Sample Record for 2025-06-09-112

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995129 DEA: 07346204 EFIS: 0718000072 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA,VEN-2,23,101-Var
Work Description: UPGRADE AND INSTALL NEW TRANSPORTATION MANAGEMENT SYSTEM ELEMENTS.
Location Description: LOS ANGELES AND VENTURA COUNTIES AT VARIOUS LOCATIONS
Contractor Name: SELECT ELECTRIC, INC.
Contractor Address: Unknown
Resident Engineer: JOSEPH SOLAIMAN TEHRANI Structure Rep.: Aziz Maghsoudloo

Sample Information

DIME Sample ID: 2025-06-09-112
TL Number from the TL Form: 019841
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/09/2025
Date that the sample was received by the laboratory/organization performing the testing: 06/11/2025
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 3/4" HMA-A
From where was the sample collected: Manufacturer
Laboratory sample identification: 25-279
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Materials Sun Valley

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 220200W SVA VLO
Binder content (%): 4.7
Virgin binder PG:
Design binder PG:
Binder Supplier: Valero
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 2

DIME Test ID: 2025-06-09-112-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/29/2025
Date Tested: 06/19/2025
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7353.3 grams
Mass of oven-dry sample in air for Sample 1 2543.2 grams
Mass of container filled with the sample and water for Sample 1 8878.1 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.497
Theoretical maximum density at 25°C (77°F) 155.4 lb/ft^3

Test 2 of 2

DIME Test ID: 2025-06-09-112-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/29/2025
Date Tested: 06/19/2025
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4056.7 g
Mass of the specimen and specimen basket assembly prior to ignition 6144.5 g
Mass of HMA Sample prior to ignition 2087.8 g
Corrected Asphalt Binder Content 5.07 %
Mass Loss 111.5 g
Mass of aggregate remaining after ignition 1976.3 g
Correction Factor (Percent by mass of HMA Specimen) 0.27 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C