Print Report | Back to Sample Detail

Sample Record for 2025-07-25-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993253 DEA: 033F0604 EFIS: 0312000052 QA Service Level: 1
DIST-CO-RTE-PM: 03-GLE-162-76.3/78.6
Work Description:
Location Description:
Contractor Name: GOLDEN STATE BRIDGE
Contractor Address: 3701 Mallard Drive, Benicia, CA 94510
Resident Engineer: Dustin Watts Structure Rep.: Matt Crete

Sample Information

DIME Sample ID: 2025-07-25-9
TL Number from the TL Form: C778919
Sample Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Sample Organization Contact: (530) 741-4238
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/25/2025
Date that the sample was received by the laboratory/organization performing the testing: 07/25/2025
The quantity of what the sample constitutes: 1/2" OGFC
A brief description of the sample: 2 Boxes
From where was the sample collected: Source
Laboratory sample identification: Daily 25-116
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Hallwood

Material Information

HMA Type: OGFC
HMA Grading: 1/2 inch
Lot number: 1
Sublot number: 3
HMA Mix Number:
Binder content (%): 0.0
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2025-07-25-9-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/25/2025
Date Tested: 07/25/2025
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: R1 OBC 5.3%
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 1635.8 g
Corrected Asphalt Binder Content 5.01 %
Mass Loss 89.7 g
Correction Factor (Percent by mass of HMA Specimen) 0.47 %
Moisture Content no data0 %
Temperature Compensation Factor 0.02 %
Test Temperature 538 C