Project Information

Project ID: 994903 DEA: 11430244 EFIS: 1118000033 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-125-9.3/13.0
Work Description: PLACE HMA, RHMA, SLAB REPLACEMENT, AND ELECTRICAL WORK.
Location Description: SAN DIEGO COUNTY IN AND NEAR LEMON GROVE FROM 0.3 MILE SOUTH OF ELKELTON PLACE UNDERCROSSING TO 0.2 MILE SOUTH OF ROUTE 125/94 SEPARATION
Contractor Name: HAZARD CONSTRUCTION ENGR LLC
Contractor Address: 10529 Vine Street, Lakeside, CA 92040
Resident Engineer: Sultan Ghazialam Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-05-29-114
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/29/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/30/2025
The quantity of what the sample constitutes: 4 boxes
A brief description of the sample: Plant Samples
From where was the sample collected: Source
Laboratory sample identification: 25-05-29-114-A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Otay

Material Information

HMA Type: RHMA-G
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 226110 Otay SJR
Binder content (%): 7.5
Virgin binder PG: PG 64-16
Design binder PG: PG 64-16
Binder Supplier:
RAP content (%): 0
WMA Additives: Yes
Antistrip type:

Test Results

Test 1 of 2

DIME Test ID: 2025-05-29-114-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/25/2025
Date Tested: 07/25/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 7.5% Tested 7.88%
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4011 g
Mass of the specimen and specimen basket assembly prior to ignition 6067.1 g
Mass of HMA Sample prior to ignition 2056.1 g
Corrected Asphalt Binder Content 7.88 %
Mass Loss 179.8 g
Mass of aggregate remaining after ignition 1876.3 g
Correction Factor (Percent by mass of HMA Specimen) 0.86 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C

Test 2 of 2

DIME Test ID: 2025-05-29-114-2
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/25/2025
Date Tested: 07/25/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target = 2.418 Tested 2.430
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7475.6 grams
Mass of oven-dry sample in air for Sample 1 2542.3 grams
Mass of container filled with the sample and water for Sample 1 8971.8 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.43
Theoretical maximum density at 25°C (77°F) 151.3 lb/ft^3