Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1001049 DEA: 061G4504 EFIS: 0623000222
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-41,180-R23.7/R24.5,R58.8
Work Description: COLD PLANE AC PAVEMENT, AND REPLACE WITH HMA.
Location Description: FRESNO COUNTY IN FRESNO ON ROUTE 41 FROM DIVISADERO STREET OVERCROSSING TO ROUTE 41/180 SEPARATION AND ON ROUTE 180 AT 0.1 MILE EAST OF ROUTE 41/180 SEPARATION
Contractor Name: CAL VALLEY CONSTRUCTION, INC.
Contractor Address: 5125 North Gates Avenue, Suite 102, Fresno, California 93722-6414
Resident Engineer: Fernando De Alba Structure Rep.: Unknown
DIME Sample ID: 2025-07-23-16
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 341-3953
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/23/2025
Date that the sample was received by the laboratory/organization performing the testing: 07/24/2025
The quantity of what the sample constitutes: 0-750 Tons Produced
A brief description of the sample: 3/4” HMA Aggregate
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta Central Ave Fresno
DIME Test ID: 2025-07-23-16-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/24/2025
Date Tested: 07/24/2025
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3973.3 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
6271.7 g
|
|
Mass of HMA Sample prior to ignition
|
2298.4 g
|
|
Corrected Asphalt Binder Content
|
4.78 %
|
|
Mass Loss
|
112.3 g
|
|
Mass of aggregate remaining after ignition
|
2186.1 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.11 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|