Print Report | Back to Sample Detail

Sample Record for 2025-07-19-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001312 DEA: 11432844 EFIS: 1125000219 QA Service Level: 1
DIST-CO-RTE-PM: 11---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Carlos Lopez Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-07-19-2
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/19/2025
Date that the sample was received by the laboratory/organization performing the testing: 07/21/2025
The quantity of what the sample constitutes: 4 Boxes
A brief description of the sample: Plant Sample
From where was the sample collected: Supplier
Laboratory sample identification: 25-07-19-2-A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Otay

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 22414 Otay SJR
Binder content (%): 4.7
Virgin binder PG: PG 64-28M
Design binder PG: PG 64-28M
Binder Supplier: San Joaquin Refinery
RAP content (%): 15
WMA Additives: No
Antistrip type:

Test Results

Test 1 of 2

DIME Test ID: 2025-07-19-2-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/24/2025
Date Tested: 07/24/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.70% Tested 4.89 %
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4035.8 g
Mass of the specimen and specimen basket assembly prior to ignition 6090.9 g
Mass of HMA Sample prior to ignition 2055.1 g
Corrected Asphalt Binder Content 4.89 %
Mass Loss 115.4 g
Mass of aggregate remaining after ignition 1939.7 g
Correction Factor (Percent by mass of HMA Specimen) 0.73 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C

Test 2 of 2

DIME Test ID: 2025-07-19-2-2
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/24/2025
Date Tested: 07/24/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target - 2.508 Tested 2.511
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7475.6 grams
Mass of oven-dry sample in air for Sample 1 2558.8 grams
Mass of container filled with the sample and water for Sample 1 9015.2 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.511
Theoretical maximum density at 25°C (77°F) 156.3 lb/ft^3