Sample Record for 2025-07-22-4
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 995193 DEA: 07356604 EFIS: 0719000026
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-605-R10.2/20.2
Work Description: LANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY.
Location Description: LOS ANGELES COUNTY IN SANTA FE SPRINGS, PICO RIVERA, WHITTIER, CITY OF INDUSTRY AND EL MONTE FROM TELEGRAPH ROAD UNDERCROSSING TO ROUTE 605/10 SEPARATION
Contractor Name: MYERS & SONS CONSTRUCTION, LLC
Contractor Address: 45 Morrison Ave, Sacramento, CA 95838
Resident Engineer: Jerome Arabe Structure Rep.: Tien Chu
Sample Information
DIME Sample ID: 2025-07-22-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 07/22/2025
Date that the sample was received by the laboratory/organization performing the testing: 07/25/2025
The quantity of what the sample constitutes: 110 hoops
A brief description of the sample: A706 GR.60 #6 x 4'-8"x 5'-5" Oval Hoops
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier: 07-356604
Structure name: LANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY
The fabricator/manufacturer/facility name: TNT Rebar Company
Material Information
Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 219925, 1202068856
Hoop Manufacturer Lot Number(s): 1
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #6
Diameter of Hoop: 4'-8"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: Cascade, Nucor
Welding Company: TNT Rebar Company
Coating Standards: Uncoated
Weld Type: Flash Welded
Test Results
Test 1 of 1
DIME Test ID: 2025-07-22-4-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 07/31/2025
Date Tested: 07/31/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
4
|
| Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | | 1 | 1 | 6 | 0.44 | 38730 | 88000 | ok necking | Kleinfelder | | 2 | 1 | 6 | 0.44 | 39910 | 90500 | ok necking | Kleinfelder | | 3 | 1 | 6 | 0.44 | 40770 | 92500 | ok necking | Kleinfelder | | 4 | 1 | 6 | 0.44 | 40200 | 91500 | ok necking | Kleinfelder |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|