Sample Record for 2025-07-11-33
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1000697 DEA: 021J75U4 EFIS: 0224000092
QA Service Level: 1
DIST-CO-RTE-PM: 02-LAS-36-14.4/R16.8
Work Description: PLACE HMA AND CLASS 2 AB, EXCAVATE ROADWAY, & INSTALL LIGHTING SYSTEM.
Location Description: LASSEN COUNTY ABOUT 9 MILES WEST OF SUSANVILLE FROM 1.3 MILES WEST TO 1.2 MILES EAST OF WILLARD CREEK ROAD
Contractor Name: HAT CREEK CONSTRUCTION & MATERIALS, INC.
Contractor Address: HAT CREEK CONSTRUCTION & MATERIALS, INC. 24339 Hwy 89 North, burney, CA, 96013
Resident Engineer: Daniel Gibbs Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2025-07-11-33
TL Number from the TL Form:
Sample Submitted By Organization: Structure Cast
Sample Organization Contact: (661) 301-2624
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 07/11/2025
Date that the sample was received by the laboratory/organization performing the testing: 07/11/2025
The quantity of what the sample constitutes: 5 CY
A brief description of the sample: Concrete Samples
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: StructureCast
Material Information
The concrete mix design number: 9SKSCC-TIT
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 16642
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Batch Plant
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 3
DIME Test ID: 2025-07-11-33-1
Test Method: ASTM C1611-21: Standard Test Method for Slump Flow of Self-Consolidating Concrete
Verified Date: 07/21/2025
Date Tested: 07/11/2025
Submitted By Organization: Structure Cast
Organization Address: 8261 McCutchen Road ,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93311
Organization Email: brent@structurecast.com
Organization Phone: (661) 717-5464
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
What unit system is used for measurements?
|
inches
|
|
Slump Flow
|
27 in
|
|
Filling the mold procedure
|
Filling Procedure B (Inverted Mold)
|
|
Diameter 1
|
27 in
|
|
Diameter 2
|
27 in
|
|
Visual Stability Index
|
no data0
|
Test 2 of 3
DIME Test ID: 2025-07-11-33-2
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 07/21/2025
Date Tested: 07/11/2025
Submitted By Organization: Structure Cast
Organization Address: 8261 McCutchen Road ,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93311
Organization Email: brent@structurecast.com
Organization Phone: (661) 717-5464
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Test 3 of 3
DIME Test ID: 2025-07-11-33-3
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 07/21/2025
Date Tested: 07/18/2025
Submitted By Organization: Structure Cast
Organization Address: 8261 McCutchen Road ,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93311
Organization Email: brent@structurecast.com
Organization Phone: (661) 717-5464
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Apparent mass of submerged cylinder 1
|
no data0 lb
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.56 in^2
|
|
Cross sectional area of cylinder 2
|
12.56 in^2
|
|
Cross sectional area of cylinder 3
|
12.56 in^2
|
|
Compressive strength (to nearest 10 psi)
|
6720 psi
|
|
Maximum load on cylinder 1
|
85483 lb
|
|
Maximum load on cylinder 2
|
83185 lb
|
|
Maximum load on cylinder 3
|
84504 lb
|
|
Type of fracture pattern of cylinder 1
|
5
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
7 days
|
|
Age of specimen in hours
|
no data0 hours
|
|
Serial number of delivery ticket, if available
|
no data
|