Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215677 DEA: 044G0804 EFIS: 0412000332 COOP: 042676
QA Service Level: 1
DIST-CO-RTE-PM: 04-SOL-80-R10.4/30.2
Work Description: Highway widening, overhead signs, and electronic toll system.
Location Description: In Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing.
Contractor Name: O.C. JONES & SONS, INC.
Contractor Address: 1520 Fourth Street, Berkeley, CA 94710
Resident Engineer: Justen Tatum Structure Rep.: Kelsey Littell
DIME Sample ID: 2025-05-23-44
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Concord Field Laboratory
Sample Organization Contact: (510) 714-7019
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/23/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/29/2025
The quantity of what the sample constitutes: 100Tons
A brief description of the sample: 1/2"HMA25%Rap-WMA
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Woodland
DIME Test ID: 2025-05-23-44-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/21/2025
Date Tested: 05/29/2025
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Specific Gravity for Sample 1
|
2.465
|
|
Theoretical maximum density at 25°C (77°F)
|
2458.1 lb/ft^3
|
DIME Test ID: 2025-05-23-44-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/21/2025
Date Tested: 05/29/2025
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
1583.2 g
|
|
Corrected Asphalt Binder Content
|
6.08 %
|
|
Mass Loss
|
112.7 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.86 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.86 %
|
|
Test Temperature
|
538 C
|