Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1720 DEA: 040G0804
QA Service Level: 1
DIST-CO-RTE-PM: 04-SON,SOL-37-4.0/R6.1,R2/R7.4
Work Description: REPLACE ASPHALT CONCRETE SURFACING
Location Description: In Sonoma and Solano Counties in and near Vallejo from Tolay Creek Bridge to 0.2 mile east of Walnut Avenue Overcrossing
Contractor Name: MB Services
Contractor Address: PO Box 5697, Concord, Ca 94524
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2025-05-02-63
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Concord Field Laboratory
Sample Organization Contact: (510) 714-7019
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/02/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/22/2025
The quantity of what the sample constitutes: 100Tons
A brief description of the sample: 3/4 HMA
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Woodland
DIME Test ID: 2025-05-02-63-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/15/2025
Date Tested: 05/23/2025
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
1643.1 g
|
|
Corrected Asphalt Binder Content
|
6.87 %
|
|
Mass Loss
|
116.5 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.57 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.18 %
|
|
Test Temperature
|
538 C
|