Print Report | Back to Sample Detail

Sample Record for 2025-07-09-50

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001213 DEA: 11431644 EFIS: 1122000232 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-78-N17.7
Work Description: Cold plane, RHMA overlay, Concrete Barriers, Landscape and Electrical.
Location Description: IN SAN DIEGO COUNTY FROM ROUTE 78/5 SEPARATION TO 0.3 MILE EAST OF ESCONDIDO BOULEVARD UNDERCROSSING.
Contractor Name: Skanska USA Civil West
Contractor Address: 1995 Agua Mansa Rd., Riverside, CA 92509
Resident Engineer: Yong Pak Structure Rep.: Carlos Lopez

Sample Information

DIME Sample ID: 2025-07-09-50
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 07/09/2025
Date that the sample was received by the laboratory/organization performing the testing: 07/14/2025
The quantity of what the sample constitutes: 17 Bags of bin aggerate
A brief description of the sample: JMF 1/2" RHMA OGFC
From where was the sample collected: Manufacturer
Laboratory sample identification: 0425O-25
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta

Material Information

Source Identification (SMARA, name of Pit or Job Site): No SMARA
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Belt cut @ Martin Marietta- Lakeside
Where the material sample would have been placed if not sampled: Asphalt Paving
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number: 21216180
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2025-07-09-50-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)07/14/2025Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory
2025-07-09-50-2AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)07/14/2025Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory
2025-07-09-50-3AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)07/14/2025Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory
2025-07-09-50-4AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)07/14/2025Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory
2025-07-09-50-5AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)07/14/2025Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory
2025-07-09-50-6AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)07/14/2025Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory
2025-07-09-50-7AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)07/14/2025Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory
2025-07-09-50-8ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)07/14/2025Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory