Print Report | Back to Sample Detail

Sample Record for 2025-07-10-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994358 DEA: 033J3304 EFIS: 0322000251 QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC-12-0/0.5
Work Description: MMBN Project. Replace backup drive system, replace lift span deck, install hydraulic barrier system and new generator, replace electrical control system, install new traffic gates and elevators, traffic control,
Location Description:
Contractor Name: Golden State Bridge, Inc.
Contractor Address: 3701 Mallard Drive, Benicia, CA 94510
Resident Engineer: Ephrem Tweldeberham Structure Rep.: Rusty D'Anna

Sample Information

DIME Sample ID: 2025-07-10-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/10/2025
Date that the sample was received by the laboratory/organization performing the testing: 07/10/2025
The quantity of what the sample constitutes: 26
A brief description of the sample: A325 Fasteners (Galvanized)
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Bay Bolt Oakland, Ca

Material Information

Rocap Number(s):
Heat Number(s): 100786789 8000034334 32028550
Nut Mfg. Lot Number(s): W000237418
Washer Mfg. Lot Number(s): 176212
Bolt Specification: A325
Bolt Length(s): 4.25"
Nut Specification: A563
Washer Specification: F436
Finish: HDG
Diameter/Size: 7/8"
Bolt Mfg. Lot Number: 392877A
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):

Test Results

Test 1 of 8

DIME Test ID: 2025-07-10-3-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 07/25/2025
Date Tested: 07/25/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 392877A
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size .875 in
Bolt Length 4.25 in
Pitch Diameter 0.8071 in
Pitch Diameter 2nd no data in

Test 2 of 8

DIME Test ID: 2025-07-10-3-2
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/25/2025
Date Tested: 07/25/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 392877A
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size .875 in
Bolt Length 4.25 in
Measurement Average 4.6 mils

Test 3 of 8

DIME Test ID: 2025-07-10-3-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/25/2025
Date Tested: 07/25/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W000237418
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size .875 in
Bolt Length no data in
Measurement Average 2.9 mils

Test 4 of 8

DIME Test ID: 2025-07-10-3-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/25/2025
Date Tested: 07/25/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 176212
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size .875 in
Bolt Length no data in
Measurement Average 2.5 mils

Test 5 of 8

DIME Test ID: 2025-07-10-3-5
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/25/2025
Date Tested: 07/25/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 392877A
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size .875 in
Bolt Length 4.25 in
Hardness Reading Scale C Scale
Hardness Reading Average 31.8
Spacing Ok

Test 6 of 8

DIME Test ID: 2025-07-10-3-6
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/25/2025
Date Tested: 07/25/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W000237418
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size .875 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 32.5
Spacing Ok

Test 7 of 8

DIME Test ID: 2025-07-10-3-7
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/25/2025
Date Tested: 07/25/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 176212
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size .875 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 39.9
Spacing Ok

Test 8 of 8

DIME Test ID: 2025-07-10-3-8
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 07/25/2025
Date Tested: 07/25/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1A392877A.8756720000000000A325Atlas
UTM NA
Temperature 0 f