Print Report | Back to Sample Detail

Sample Record for 2025-06-10-103

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000540 DEA: 051Q03U4 EFIS: 0524000192 QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO,KER-46-60.3/60.8,0.0/0.4
Work Description: VERTICAL CURVE AND EXTEND EXISTING TRUCK CLIMBING LANE.
Location Description: SAN LUIS OBISPO AND KERN COUNTIES NEAR CHOLAME FROM 2.0 MILES EAST OF ANTELOPE ROAD TO 0.4 MILE EAST OF THE KERN COUNTY LINE.
Contractor Name: PAPICH CONSTRUCTION COMPANY, INC.
Contractor Address: Unknown
Resident Engineer: Andrew Borelli Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-06-10-103
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Whitley Gardens Field Laboratory
Sample Organization Contact: 805-540-9933
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 06/10/2025
Date that the sample was received by the laboratory/organization performing the testing: 06/11/2025
The quantity of what the sample constitutes: RCB Invert & Cutoff Wall
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Manufacturer
Laboratory sample identification: 250610 590RN1010- Set 1
Structure unique identifier:
Structure name: RCB Invert & Cutoff Wall
The fabricator/manufacturer/facility name: CalPortland Paso Robles

Material Information

The concrete mix design number: 590RN1010
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Mix Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2025-06-10-103-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 07/09/2025
Date Tested: 07/08/2025
Submitted By Organization: CT D05 - Whitley Gardens Field Laboratory
Organization Address: 102 South Whitley Gardens Drive,
Organization City: Paso Robles
Organization State: CA
Organization Zipcode: 93346
Organization Email: kyle.engen@dot.ca.gov
Organization Phone: (805) 540-9933
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 4360 psi
Maximum load on cylinder 1 54328 lb
Maximum load on cylinder 2 53616 lb
Maximum load on cylinder 3 56566 lb
Compressive strength of cylinder 1 4322.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4265.4 psi
Compressive strength of cylinder 3 4500.1 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours