Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000117 DEA: 020J0104 EFIS: 0219000044
QA Service Level: 1
DIST-CO-RTE-PM: 02-TEH-99-4.2/4.8
Work Description: PLACE HMA, CCTV TOWER AND INSTALL LIGHTING SYSTEM.
Location Description: TEHAMA COUNTY ABOUT 7.0 MILES SOUTH OF LOS MOLINOS FROM 0.3 MILE SOUTH OF SOUTH AVENUE TO 0.6 MILE SOUTH OF VINA ROAD
Contractor Name: BALDWIN CONTRACTING COMPANY, INC. DBA KNIFE RIVER CONSTRUCTION
Contractor Address: 1764 Skyway, Chico, CA 95928
Resident Engineer: Edward Worden Structure Rep.: Chris Brace
DIME Sample ID: 2025-06-27-25
TL Number from the TL Form: 858141
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/27/2025
Date that the sample was received by the laboratory/organization performing the testing: 07/01/2025
The quantity of what the sample constitutes: 2 box HMA
A brief description of the sample: 3/4" HMA-A
From where was the sample collected: Manufacturer
Laboratory sample identification: D79937
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Knife River, Orland
DIME Test ID: 2025-06-27-25-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/09/2025
Date Tested: 07/02/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmmr=2.573
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7334 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2567.1 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8903.4 grams
|
|
Temperature of Water
|
76 °F
|
|
Specific Gravity for Sample 1
|
2.573
|
|
Theoretical maximum density at 25°C (77°F)
|
2565.5 kg/m^3
|
DIME Test ID: 2025-06-27-25-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/09/2025
Date Tested: 07/07/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pb=4.50%
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3153.1 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5213.2 g
|
|
Mass of HMA Sample prior to ignition
|
2060.1 g
|
|
Corrected Asphalt Binder Content
|
4.5 %
|
|
Mass Loss
|
112 g
|
|
Mass of aggregate remaining after ignition
|
1948.1 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.79 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.15 %
|
|
Test Temperature
|
482 C
|