Print Report | Back to Sample Detail

Sample Record for 2025-07-07-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994574 DEA: 050C7334 EFIS: 0518000116 QA Service Level: 1
DIST-CO-RTE-PM: 05-SCR-1-10.5/13.4
Work Description: CONSTRUCT OVERCROSSING AND AUXILIARY LANE/ Replace Capitola Ave OC + RWs and SWs
Location Description: SANTA CRUZ COUNTY IN AND NEAR CITY OF CAPITOLA FROM STATE PARK DRIVE OVERCROSSING TO 0.2 MILE NORTH OF BAY AVENUE UNDERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 580 West Beach Street, Watsonville, CA 95076
Resident Engineer: Fernando Dos Santos Structure Rep.: Daniel Dait

Sample Information

DIME Sample ID: 2025-07-07-9
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 07/07/2025
Date that the sample was received by the laboratory/organization performing the testing: 07/11/2025
The quantity of what the sample constitutes: 276
A brief description of the sample: #8 5'-2" Welded Hoops
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: TNT Rebar

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 1201066160,1201066165,1202067392
Hoop Manufacturer Lot Number(s): 1,2
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #8
Diameter of Hoop: 5'-2"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: NUCOR
Welding Company: TNT Rebar Company
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Results

Test 1 of 1

DIME Test ID: 2025-07-07-9-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 07/23/2025
Date Tested: 07/23/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 8
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1180.797799098500ok neckingKleinfelder
2180.797763098500ok neckingKleinfelder
3180.797744098000ok neckingKleinfelder
4180.797775098500ok neckingKleinfelder
1280.797284092000ok neckingKleinfelder
2280.797557095500ok neckingKleinfelder
3280.797351093000ok neckingKleinfelder
4280.797558095500ok neckingKleinfelder
UTM NA
Temperature 0 f