Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000636 DEA: 024H03U4 EFIS: 0224000026
QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-89-12.9/20.0,20.6/21.0
Work Description: HMA OVERLAY.
Location Description: PLUMAS COUNTY IN AND NEAR GREENVILLE FROM 0.8 MILE SOUTH OF DIXIE CANYON ROAD TO WOLF CREEK BRIDGE AND FROM MILL STREET TO 0.4 MILE NORTH OF HILLSIDE DRIVE
Contractor Name: HAT CREEK CONSTRUCTION & MATERIALS, INC.
Contractor Address: Unknown
Resident Engineer: Damion Farley Structure Rep.: Unknown
DIME Sample ID: 2025-06-17-100
TL Number from the TL Form:
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Production Start-Up
Type of Material: Aggregate
Sample Taken Date: 06/17/2025
Date that the sample was received by the laboratory/organization performing the testing: 06/18/2025
The quantity of what the sample constitutes: Production Start-Up Evaluation
A brief description of the sample: 1 bag of Combined Lime Treated 1/2-inch Virgin Aggregate
From where was the sample collected: Manufacturer
Laboratory sample identification: D79907
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hat Creek Construction & Materials — Ward Lake Plant (Litchfield, CA)
Source Identification (SMARA, name of Pit or Job Site): 91-18-0008::Ward Lake Pit (Litchfield, CA)
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Cold Feed Sampling Chute
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:
DIME Test ID: 2025-06-17-100-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 06/26/2025
Date Tested: 06/26/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
What type of gradation is being tested?
|
Combined Gradation
|
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
95 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
82 %
|
|
Cumulative percent passing the #4 sieve
|
50 %
|
|
Cumulative percent passing the #8 sieve
|
30 %
|
|
Cumulative percent passing the #16 sieve
|
19 %
|
|
Cumulative percent passing the #30 sieve
|
13 %
|
|
Cumulative percent passing the #50 sieve
|
9 %
|
|
Cumulative percent passing the #100 sieve
|
6 %
|
|
Cumulative percent passing the #200 sieve
|
4.6 %
|