Print Report | Back to Sample Detail

Sample Record for 2025-06-19-53

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000234 DEA: 112N1774 EFIS: 1123000036 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-15,52-Var
Work Description: MICRO-SURFACING, HMA, PAVEMENT MARKING AND SHOULDER BACKING.
Location Description: SAN DIEGO COUNTY AT VARIOUS LOCATIONS
Contractor Name: GRIFFITH COMPANY
Contractor Address: Unknown
Resident Engineer: Peris Salih Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-06-19-53
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Aggregate
Sample Taken Date: 06/19/2025
Date that the sample was received by the laboratory/organization performing the testing: 06/20/2025
The quantity of what the sample constitutes: 4 bags
A brief description of the sample: JMF
From where was the sample collected: Supplier
Laboratory sample identification: 25-06-19-53-JMF
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-37-0035
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number: 320912 Otay Val

Test Results

Test 1 of 12

DIME Test ID: 2025-06-19-53-6
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 07/02/2025
Date Tested: 06/27/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Sand Equivalent 72

Test 2 of 12

DIME Test ID: 2025-06-19-53-14
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Verified Date: 07/02/2025
Date Tested: 06/30/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Plastic limit (PL) 1 %

Test 3 of 12

DIME Test ID: 2025-06-19-53-4
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 07/02/2025
Date Tested: 06/30/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method 1 - Combined Fracture Determination
Aggregate Size and Fracture Type Coarse 1 and 2 Faced
Percentage of questionable, coarse, 2 faced particles tested no data0 %
Percentage of questionable, coarse, 1 faced particles tested no data0 %
Percentage of fractured, coarse, 2 faced particles tested 99 %
Percentage of fractured, coarse, 1 faced particles tested 99 %

Test 4 of 12

DIME Test ID: 2025-06-19-53-5
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 07/02/2025
Date Tested: 06/30/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method A
Determination By Number
Dimensional ratio used 5:1
Weighted percentage of particles (by number) that were flat no data0 %
Weighted percentage of particles (by number) that were elongated 0 %
Weighted percentage of particles (by number) that were both flat and elongated 4 %
Weighted percentage of particles (by number) that were neither flat nor elongated 96 %

Test 5 of 12

DIME Test ID: 2025-06-19-53-2
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 07/02/2025
Date Tested: 06/30/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 90 %
Cumulative percent passing the 3/8 in. sieve 77 %
Cumulative percent passing the #4 sieve 52 %
Cumulative percent passing the #8 sieve 40 %
Cumulative percent passing the #16 sieve 31 %
Cumulative percent passing the #30 sieve 20 %
Cumulative percent passing the #50 sieve 11 %
Cumulative percent passing the #100 sieve 5 %
Cumulative percent passing the #200 sieve 3.4 %

Test 6 of 12

DIME Test ID: 2025-06-19-53-7
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 07/02/2025
Date Tested: 07/01/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Bulk specific gravity 2.617
Bulk specific gravity (SSD Basis) 2.661
Apparent specific gravity 2.736
Absorption 1.7 %

Test 7 of 12

DIME Test ID: 2025-06-19-53-8
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 07/02/2025
Date Tested: 07/01/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Spg. 2.676 - 2.752
Test Result Compliance: complies
Additional Comments When Verified:
Basis for relative density testing Bulk SSD
Specific Gravity 2.741
Absorption 1.1 %

Test 8 of 12

DIME Test ID: 2025-06-19-53-10
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 07/02/2025
Date Tested: 07/01/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Target - 45 min
Test Result Compliance: complies
Additional Comments When Verified:
What test method is performed? Method A
Bulk dry specific gravity 2.617
Average uncompacted voids 45.8 %

Test 9 of 12

DIME Test ID: 2025-06-19-53-9
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 07/02/2025
Date Tested: 07/01/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Grading designation C
Mass of sample on No.12 sieve (after 500 revolutions) 4279 grams
Percent loss after 100 revolutions 7 %
Percent loss after 500 revolutions 14 %

Test 10 of 12

DIME Test ID: 2025-06-19-53-11
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/02/2025
Date Tested: 07/01/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: RAP Rice Target - 2.403 to 2.523
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7475.6 grams
Mass of oven-dry sample in air for Sample 1 1520.7 grams
Mass of container filled with the sample and water for Sample 1 8379.4 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.465
Theoretical maximum density at 25°C (77°F) 153.4 lb/ft^3

Test 11 of 12

DIME Test ID: 2025-06-19-53-13
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 07/03/2025
Date Tested: 07/01/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: RAP
Test Result Compliance: not applicable
Additional Comments When Verified:
Is an aggregate correction factor used? No
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 99 %
Cumulative percent passing the 3/8 in. sieve 96 %
Cumulative percent passing the #4 sieve 77 %
Cumulative percent passing the #8 sieve 58 %
Cumulative percent passing the #16 sieve 44 %
Cumulative percent passing the #30 sieve 33 %
Cumulative percent passing the #50 sieve 22 %
Cumulative percent passing the #100 sieve 15 %
Cumulative percent passing the #200 sieve 10.5 %

Test 12 of 12

DIME Test ID: 2025-06-19-53-12
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 07/07/2025
Date Tested: 07/03/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Is an aggregate correction factor used? No
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 98 %
Cumulative percent passing the 3/8 in. sieve 94 %
Cumulative percent passing the #4 sieve 73 %
Cumulative percent passing the #8 sieve 56 %
Cumulative percent passing the #16 sieve 41 %
Cumulative percent passing the #30 sieve 29 %
Cumulative percent passing the #50 sieve 18 %
Cumulative percent passing the #100 sieve 11 %
Cumulative percent passing the #200 sieve 6.7 %