Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 995538 DEA: 024H0604 EFIS: 0218000073
QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU,PLU-36-
Work Description: CHESTER CAUSEWAY REHAB
Location Description: LASSEN AND PLUMAS COUNTIES FROM MELISSA AVENUE TO 0.6 MILE EAST OF RED RIVER CANAL
Contractor Name: HAT CREEK CONSTRUCTION & MATERIALS, INC.
Contractor Address: Unknown
Resident Engineer: Daniel Gibbs Structure Rep.: Unknown
DIME Sample ID: 2025-06-16-54
TL Number from the TL Form: 877787
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/16/2025
Date that the sample was received by the laboratory/organization performing the testing: 06/20/2025
The quantity of what the sample constitutes: 750 tons
A brief description of the sample: 1 pan of Lime Treated 3/4-inch Type A HMA (eq. PG 64-28)
From where was the sample collected: Manufacturer
Laboratory sample identification: D79914
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hat Creek Construction & Materials — Ward Lake Plant (Litchfield, CA)
HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 2412008
Binder content (%): 5.7
Virgin binder PG:
Design binder PG: PG 64-28
Binder Supplier: Albina (Klamath Falls, OR)
RAP content (%): 22
WMA Additives:
Antistrip type: 1.0% Lime
DIME Test ID: 2025-06-16-54-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/25/2025
Date Tested: 06/23/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pb=5.29
Test Result Compliance: does not comply
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3039.2 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5358.5 g
|
|
Mass of HMA Sample prior to ignition
|
2319.3 g
|
|
Corrected Asphalt Binder Content
|
5.29 %
|
|
Mass Loss
|
145.8 g
|
|
Mass of aggregate remaining after ignition
|
2173.5 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.87 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.13 %
|
|
Test Temperature
|
538 C
|