Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000751 DEA: 060Y1704 EFIS: 0619000004
QA Service Level: 1
DIST-CO-RTE-PM: 06-KIN-41-0.0/15.5
Work Description: COLD PLANE AC PVMT, OVERLAY HMA AND RHMA.
Location Description: KINGS COUNTY NEAR KETTLEMAN CITY FROM THE KERN COUNTY LINE TO 0.8 MILE SOUTH OF ROUTE 5
Contractor Name: PAPICH CONSTRUCTION COMPANY, INC.
Contractor Address: Unknown
Resident Engineer: Oscar Sherrill Structure Rep.: Ramandeep Guraya
DIME Sample ID: 2025-06-16-11
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 341-3953
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/16/2025
Date that the sample was received by the laboratory/organization performing the testing: 06/16/2025
The quantity of what the sample constitutes: 1525 tons
A brief description of the sample: 3/4 hma
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sierra Pacific - Avenal
DIME Test ID: 2025-06-16-11-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/18/2025
Date Tested: 06/18/2025
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
2878 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
4984 g
|
|
Mass of HMA Sample prior to ignition
|
2106 g
|
|
Corrected Asphalt Binder Content
|
4.69 %
|
|
Mass Loss
|
123.4 g
|
|
Mass of aggregate remaining after ignition
|
1982.6 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
1.04 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.13 %
|
|
Test Temperature
|
482 C
|