Print Report | Back to Sample Detail

Sample Record for 2017-07-13-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211931 DEA: 043G6414 EFIS: 0416000348 QA Service Level: 1
DIST-CO-RTE-PM: 04-NAP-29-37.0
Work Description: SCOUR REPLACE BRIDGE
Location Description: NAPA COUNTY IN CALISTOGA AT NAPA RIVER BRIDGE
Contractor Name: Valentine Corp.
Contractor Address: 111 Pelican Way, San Rafael, CA 94901
Resident Engineer: Danilo Patenia Structure Rep.: Nana Budu

Sample Information

DIME Sample ID: 2017-07-13-5
TL Number from the TL Form: C647232
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 07/13/2017
Date that the sample was received by the laboratory/organization performing the testing: 07/17/2017
The quantity of what the sample constitutes: 2
A brief description of the sample: Williams Thread Bars
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Williams Forms

Material Information

Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 75
Threaded Bar Type: Deformed
Rebar Size: #9
Nut Specification for Threaded Bar: 75
System Manufacturer: Williams Form
Epoxy Coating Color: Purple
Threaded Bar Application: Threaded Bar
Coating Standards: ASTM A934 epoxy
Bar Heat Number(s): 100786966
Nut Heat Number(s): 9H5D
Bar Lot Number: Unknown
Nut Lot Number: Unknown
Coupler Heat Number(s): 9H2D
Coupler Grade: 75

Test Results

Test

DIME Test ID: 2017-07-13-5-1
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 07/20/2017
Date Tested: 07/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test: A615 Bar, Nut & Coupler
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
1#9 Williams Bar , Nut ##9H5D, Coupler #9H2DL73005171128072993480A615 Bar, Nut & CouplerFred
Temperature 72 F
UTM 400KIP

Test

DIME Test ID: 2017-07-13-5-3
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 07/20/2017
Date Tested: 07/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Lower spec. limit LSL 10 mils
Upper spec. limit USL 15 mils
Bar # for First Bar 1
Bar # for Second Bar 2
First Bar Mean 9.6 mils
Second Bar Mean 9.3 mils
Total mean value 9.45 mils