Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994546 DEA: 030H3704 EFIS: 0315000151
QA Service Level: 1
DIST-CO-RTE-PM: 03-YUB-65-R0.5/1.8
Work Description: PLACE HMA, RHMA & CONC CURB/SIDEWALK, INSTALL & MODIFY SIGNAL SYSTEMS.
Location Description: YUBA COUNTY NEAR WHEATLAND FROM 0.2 MILE SOUTH OF MAIN STREET TO GRASSHOPPER SLOUGH BRIDGE
Contractor Name: BALDWIN CONTRACTING CO., INC. DBA KNIFE RIVER CONSTRUCTION
Contractor Address: 1764 Skyway, Chico, CA 95928
Resident Engineer: Dustin Watts Structure Rep.: Unknown
DIME Sample ID: 2025-06-10-40
TL Number from the TL Form: C802582
Sample Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Sample Organization Contact: (530) 741-4238
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/10/2025
Date that the sample was received by the laboratory/organization performing the testing: 06/11/2025
The quantity of what the sample constitutes: 1/2" RHMA-O
A brief description of the sample: 2 Boxes
From where was the sample collected: Source
Laboratory sample identification: Daily 25-073
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: KRC - Hallwood
DIME Test ID: 2025-06-10-40-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/12/2025
Date Tested: 06/11/2025
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: L1
OBC 7.3%
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
1655.5 g
|
|
Corrected Asphalt Binder Content
|
7.17 %
|
|
Mass Loss
|
125.9 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.43 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.02 %
|
|
Test Temperature
|
538 C
|