Print Report | Back to Sample Detail

Sample Record for 2025-06-02-57

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000698 DEA: 024H0704 EFIS: 0218000074 QA Service Level: 1
DIST-CO-RTE-PM: 02-LAS-139-0.74/11.0
Work Description: PLACE HMA (TYPE A), TRAFFIC CONTROL SYSTEM, TRAFFIC STRIPE, RDWY EXC.
Location Description: LASSEN COUNTY NEAR SUSANVILLE FROM 0.1 MILE NORTH OF CHESTNUT STREET TO 2.6 MILES SOUTH OF HORSE LAKE ROAD
Contractor Name: HAT CREEK CONSTRUCTION & MATERIALS, INC.
Contractor Address: Unknown
Resident Engineer: Daniel Gibbs Structure Rep.: Tooraj Yegan

Sample Information

DIME Sample ID: 2025-06-02-57
TL Number from the TL Form: 877780
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/02/2025
Date that the sample was received by the laboratory/organization performing the testing: 06/09/2025
The quantity of what the sample constitutes: 750 tons
A brief description of the sample: 1 pan of Lime Treated 3/4-inch Type A HMA (eq. PG 64-28)
From where was the sample collected: Manufacturer
Laboratory sample identification: D79900
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hat Creek Construction & Materials — Ward Lake Plant (Litchfield, CA)

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2025-06-02-57-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/12/2025
Date Tested: 06/10/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: PB=5.78
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3153.3 g
Mass of the specimen and specimen basket assembly prior to ignition 5394.6 g
Mass of HMA Sample prior to ignition 2241.3 g
Corrected Asphalt Binder Content 5.79 %
Mass Loss 152.1 g
Mass of aggregate remaining after ignition 2089.2 g
Correction Factor (Percent by mass of HMA Specimen) 0.87 %
Moisture Content no data0 %
Temperature Compensation Factor 0.13 %
Test Temperature 538 C