Sample Record for 2017-07-17-2
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 211931 DEA: 043G6414 EFIS: 0416000348
QA Service Level: 1
DIST-CO-RTE-PM: 04-NAP-29-37.0
Work Description: SCOUR REPLACE BRIDGE
Location Description: NAPA COUNTY IN CALISTOGA AT NAPA RIVER BRIDGE
Contractor Name: Valentine Corp.
Contractor Address: 111 Pelican Way, San Rafael, CA 94901
Resident Engineer: Danilo Patenia Structure Rep.: Nana Budu
Sample Information
DIME Sample ID: 2017-07-17-2
TL Number from the TL Form: C882751
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 07/17/2017
Date that the sample was received by the laboratory/organization performing the testing: 07/18/2017
The quantity of what the sample constitutes: 4
A brief description of the sample: Bartec Couplers
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Gerdau Dextra Nucor
Material Information
Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Gerdau Nucor
Coupler Manufacturer: Dextra America
Intermediate Assembler or Fabricator: Unknown
Rebar Size: #8
Coupler Model: Bartec
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter: Unknown
Rebar Hoop Fabricator: Unknown
Coupler Component Heat/Lot Number(s): 03732
Rebar Heat Number(s): PL17200824, 65026858
Rebar Size 2 :
Coupler Unique ID:
Test Results
Test 1 of 3
DIME Test ID: 2017-07-17-2-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Verified Date: 07/19/2017
Date Tested: 07/18/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; Ok Necking
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
1
|
| Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | | 1 | C01 | #8/25mm | 0.79 | -0.0007 | 71921 | 91039 | Bar Broke | Fred |
| |
|
Temperature
|
72 F
|
|
UTM
|
400KIP
|
|
Halo ID
|
Small
|
Test 2 of 3
DIME Test ID: 2017-07-17-2-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Verified Date: 07/19/2017
Date Tested: 07/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; Ok Necking
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
1
|
| Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | | 2 | C01 | #8/25mm | 0.79 | 0 | 71938 | 91061 | Bar Broke | Fred |
| |
|
Temperature
|
72 F
|
|
UTM
|
400KIP
|
|
Halo ID
|
Small
|
Test 3 of 3
DIME Test ID: 2017-07-17-2-3
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Verified Date: 07/19/2017
Date Tested: 07/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; Ok Necking
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
1
|
| Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | | 3 | C01 | #8/25mm | 0.79 | 0 | 71654 | 90701 | Bar Broke | Fred |
| |
|
Temperature
|
72 F
|
|
UTM
|
400KIP
|
|
Halo ID
|
Small
|