Print Report | Back to Sample Detail

Sample Record for 2025-03-12-17

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000279 DEA: 023H70U4 EFIS: 0223000161 QA Service Level: 1
DIST-CO-RTE-PM: 02-TRI-299-15.0/25.7
Work Description: RHMA-G, HMA (TYPE A), COLD PLANE AC, & SOLDIER PILE RETAINING WALL.
Location Description: TRINITY COUNTY NEAR DEL LOMA FROM 1.0 MILE EAST OF TRINITY RIVER BRIDGE NO.05-0006 TO 0.1 MILE WEST OF PRAIRIE CREEK ROAD
Contractor Name: J.F. SHEA CONSTRUCTION, INC.
Contractor Address: Unknown
Resident Engineer: Edward Worden Structure Rep.: Mike Sears

Sample Information

DIME Sample ID: 2025-03-12-17
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 03/12/2025
Date that the sample was received by the laboratory/organization performing the testing: 06/02/2025
The quantity of what the sample constitutes: 5 quart cans
A brief description of the sample: Asphalt Rubber Binder, PG 64-16 CR
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: American Pavement Systems

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2025-03-12-17-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 06/10/2025
Date Tested: 06/03/2025
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: Softening Point
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 66 C
Softening Point Sample 2 66 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test 2 of 3

DIME Test ID: 2025-03-12-17-2
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 06/10/2025
Date Tested: 06/03/2025
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: Cone Penetration
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 34 0.1 mm

Test 3 of 3

DIME Test ID: 2025-03-12-17-3
Test Method: ASTM D5329-20: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 06/10/2025
Date Tested: 06/09/2025
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: Resilience
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Ball Penetration (P1) 5 mm
Final Dial reading (F1) 60 mm
Ball Penetration (P2) 6 mm
Final Dial reading (F2) 59 mm
Ball Penetration (P3) 5 mm
Final Dial reading (F3) 62 mm
Resilience 1 45 %
Resilience 2 47 %
Resilience 3 43 %
Average Resilience 45 %
Minutes Reaction no data